Stanovení polybromovaných difenyletherů ve vzorcích mateřského mléka v České republice. Studie porovnávající hmotnostní spektrometrii s negativní chemickou ionizací a time of flight vysokorozlišovací hmotnostní spektrometrii
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F04%3A00013083" target="_blank" >RIV/60461373:22330/04:00013083 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of polybrominated diphenyl ethers in human milk samples in the Czech Republic. Comparative study of negative chemical ionisation mass spectrometry and time-of-flight high-resolution mass spectrometry
Popis výsledku v původním jazyce
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid-liquid extraction (LLE)(hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC-MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g-1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002-0.005 ng g-1 lipid weight, what enabled detection of minor PBDE congeners. Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc reg
Název v anglickém jazyce
Determination of polybrominated diphenyl ethers in human milk samples in the Czech Republic. Comparative study of negative chemical ionisation mass spectrometry and time-of-flight high-resolution mass spectrometry
Popis výsledku anglicky
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid-liquid extraction (LLE)(hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC-MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g-1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002-0.005 ng g-1 lipid weight, what enabled detection of minor PBDE congeners. Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc reg
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Anal.Chim.Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
520
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
237-243
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—