Stanovení oxohalogenidů v pitné vodě metodou on-line spojení kapilární isotachoforesa - zónová elektroforesa
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F05%3A00016013" target="_blank" >RIV/60461373:22330/05:00016013 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of inorganic oxyhalides in drinking
Popis výsledku v původním jazyce
Some oxyhalides can be found in drinking waters as inorganic disinfection by-products. An on-line coupled capillary isotachophoresis - capillary zone electrophoresis (CITP-CZE) method was developed for the analysis of chlorate, chlorite and bromate in water. The optimized CITP-CZE electrolyte system consisted of the following: 10 mM - HCl + 20mM - -Alanine (leading electrolyte), 5 mM - succinic acid (terminating electrolyte), and 10 mM - succinic acid + 5 mM - -Alanine + 0.1 % HPMC (carrier electrolyte). A clear separation of oxyhalides from other components of drinking water was achieved within 25 min. Method characteristics, i.e., linearity (0-200 ng/mL), accuracy (88-110 %), intra-assay (3-5 %), quantification limit (5-15 ng/mL), and detection limit(2-5 ng/mL), were determined. Minimum labor requirements, sufficient sensitivity and low running cost are important attributes of this method. It was found that the developed method is useful for the routine analysis of oxyhalides in wat
Název v anglickém jazyce
Determination of inorganic oxyhalides in drinking
Popis výsledku anglicky
Some oxyhalides can be found in drinking waters as inorganic disinfection by-products. An on-line coupled capillary isotachophoresis - capillary zone electrophoresis (CITP-CZE) method was developed for the analysis of chlorate, chlorite and bromate in water. The optimized CITP-CZE electrolyte system consisted of the following: 10 mM - HCl + 20mM - -Alanine (leading electrolyte), 5 mM - succinic acid (terminating electrolyte), and 10 mM - succinic acid + 5 mM - -Alanine + 0.1 % HPMC (carrier electrolyte). A clear separation of oxyhalides from other components of drinking water was achieved within 25 min. Method characteristics, i.e., linearity (0-200 ng/mL), accuracy (88-110 %), intra-assay (3-5 %), quantification limit (5-15 ng/mL), and detection limit(2-5 ng/mL), were determined. Minimum labor requirements, sufficient sensitivity and low running cost are important attributes of this method. It was found that the developed method is useful for the routine analysis of oxyhalides in wat
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F03%2F0351" target="_blank" >GA525/03/0351: Použití kapilární elektroforesy pro analýzu bioaktivních látek v potravinách</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1644-3624
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
9
Strana od-do
137-145
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—