Optimalizace metody pro stanovení polycyklických aromatických uhlovodíků v rybách; odhad nejistoty metody
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F06%3A00017805" target="_blank" >RIV/60461373:22330/06:00017805 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimisation of procedure for determination of polycyclic aromatic hydrocarbons and their derivatives in fish tissue: Estimation of measurements uncertainty
Popis výsledku v původním jazyce
Three alternative procedures were employed for isolation of polycyclic aromatic hydrocarbons (PAHs), their methyl-derivatives and sulphur analogues from fish tissue: (i) Soxhlet extraction, (ii) batch extraction enhanced by sonication and (iii) saponification of sample followed by reextraction of analytes into hexane. Soxhlet extraction using hexane-acetone (1:1, v/v) was found as the most efficient extraction technique, with analyte recoveries in the range 70-108 %. Within optimisation of clean-up step, several types of gel permeation chromatography (GPC) systems were tested: two types of polystyrene divinylbenzene copolymer gels (PSDVB), both "soft" gel type (Bio-Beads S-X3) and "rigid" gels type (PL gel and Envirogel) in combination with various mobile phases were compared. Bio-Beads S-X3 and mobile phase chloroform were found as the most appropriate for purifying of crude extracts prior to the final determinative step. High performance liquid chromatography with fluorimetric de
Název v anglickém jazyce
Optimisation of procedure for determination of polycyclic aromatic hydrocarbons and their derivatives in fish tissue: Estimation of measurements uncertainty
Popis výsledku anglicky
Three alternative procedures were employed for isolation of polycyclic aromatic hydrocarbons (PAHs), their methyl-derivatives and sulphur analogues from fish tissue: (i) Soxhlet extraction, (ii) batch extraction enhanced by sonication and (iii) saponification of sample followed by reextraction of analytes into hexane. Soxhlet extraction using hexane-acetone (1:1, v/v) was found as the most efficient extraction technique, with analyte recoveries in the range 70-108 %. Within optimisation of clean-up step, several types of gel permeation chromatography (GPC) systems were tested: two types of polystyrene divinylbenzene copolymer gels (PSDVB), both "soft" gel type (Bio-Beads S-X3) and "rigid" gels type (PL gel and Envirogel) in combination with various mobile phases were compared. Bio-Beads S-X3 and mobile phase chloroform were found as the most appropriate for purifying of crude extracts prior to the final determinative step. High performance liquid chromatography with fluorimetric de
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Food Additives and Contaminants
ISSN
0265-203X
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
17
Strana od-do
309-325
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—