Rapid method for simultaneous determination of PCBs, PBDEs and PAHs in fish samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F09%3A00022380" target="_blank" >RIV/60461373:22330/09:00022380 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid method for simultaneous determination of PCBs, PBDEs and PAHs in fish samples
Popis výsledku v původním jazyce
Analytical methods for determination of various organic contaminants such as polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and polyaromatic hydrocarbons (PAHs) in environmental and food matrices are typically based on multistepprocedures that include Soxhlet extraction with a subsequent clean up and fractionation steps prior to relatively slow gas chromatography (GC) runs using either an electron capture (ECD) or a mass spectrometric (MS) detection in case of halogenated analytes, PAHs are commonly analysed separately using a liquid chromatography coupled to a fluorescence detector (LC-FLD), but for several non-flurescence PAHs including in the EFSA opinion, a GC-MS analysis is needed. In this study, the fast extraction andclean-up procedure of all mentioned pollutants from a fish fillet by a pressurised liquid extraction (PLE) has been tested. The main goal was to optimize an appropriate extraction/clean up procedure and to demonstrate the separation power
Název v anglickém jazyce
Rapid method for simultaneous determination of PCBs, PBDEs and PAHs in fish samples
Popis výsledku anglicky
Analytical methods for determination of various organic contaminants such as polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and polyaromatic hydrocarbons (PAHs) in environmental and food matrices are typically based on multistepprocedures that include Soxhlet extraction with a subsequent clean up and fractionation steps prior to relatively slow gas chromatography (GC) runs using either an electron capture (ECD) or a mass spectrometric (MS) detection in case of halogenated analytes, PAHs are commonly analysed separately using a liquid chromatography coupled to a fluorescence detector (LC-FLD), but for several non-flurescence PAHs including in the EFSA opinion, a GC-MS analysis is needed. In this study, the fast extraction andclean-up procedure of all mentioned pollutants from a fish fillet by a pressurised liquid extraction (PLE) has been tested. The main goal was to optimize an appropriate extraction/clean up procedure and to demonstrate the separation power
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7E08068" target="_blank" >7E08068: CONtaminants in Food and Feed: Inexpensive DEtectioN for Control of Exposure</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Organohalogen Compounds
ISSN
1026-4892
e-ISSN
—
Svazek periodika
71
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—