Analysis of anabolic androgenic steroids by direct analysis in real time ionization with time-of-flight mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F15%3A43899512" target="_blank" >RIV/60461373:22330/15:43899512 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1387380615002730" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1387380615002730</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijms.2015.08.022" target="_blank" >10.1016/j.ijms.2015.08.022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of anabolic androgenic steroids by direct analysis in real time ionization with time-of-flight mass spectrometry
Popis výsledku v původním jazyce
We verified applicability of direct analysis in real time ionization coupled with a time-of-flight mass spectrometer (DART-MS) for detection of anabolic androgenic steroids in supplements and pharmaceuticals. DART-MS was optimized for the analysis of eleven frequently misused anabolic androgenic steroids and their derivatives. Real supplement tablets and injectable oil solutions were used to verify applicability of the method. It was found that anabolic androgenic steroids can be analyzed directly without any sample pre-treatment, which reduces the sample preparation time and hence the overall analysis time. The resulting DART-MS method is suitable for rapid routine qualitative screening of anabolic androgenic steroids in simple sample matrices. It has a great potential in the field of adulterated and counterfeited anabolic steroid pharmaceuticals and supplements.
Název v anglickém jazyce
Analysis of anabolic androgenic steroids by direct analysis in real time ionization with time-of-flight mass spectrometry
Popis výsledku anglicky
We verified applicability of direct analysis in real time ionization coupled with a time-of-flight mass spectrometer (DART-MS) for detection of anabolic androgenic steroids in supplements and pharmaceuticals. DART-MS was optimized for the analysis of eleven frequently misused anabolic androgenic steroids and their derivatives. Real supplement tablets and injectable oil solutions were used to verify applicability of the method. It was found that anabolic androgenic steroids can be analyzed directly without any sample pre-treatment, which reduces the sample preparation time and hence the overall analysis time. The resulting DART-MS method is suitable for rapid routine qualitative screening of anabolic androgenic steroids in simple sample matrices. It has a great potential in the field of adulterated and counterfeited anabolic steroid pharmaceuticals and supplements.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20112015045" target="_blank" >VG20112015045: Vývoj rychlých imunochemických testů pro detekci anabolicky aktivních steroidů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Mass Spectrometry
ISSN
1387-3806
e-ISSN
—
Svazek periodika
392
Číslo periodika v rámci svazku
DEC 3 2015
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
28-33
Kód UT WoS článku
000366441700005