Antibodies Modified by Gold Nanoparticles or Quantum Dots For Specific Detection of Sarcosine on The Membrane: Use in Rapid Diagnostics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F18%3A43915222" target="_blank" >RIV/60461373:22330/18:43915222 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/18:10392581
Výsledek na webu
<a href="https://www.nanocon.eu/files/uploads/01/NANOCON2017_Proceedings_content.pdf" target="_blank" >https://www.nanocon.eu/files/uploads/01/NANOCON2017_Proceedings_content.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Antibodies Modified by Gold Nanoparticles or Quantum Dots For Specific Detection of Sarcosine on The Membrane: Use in Rapid Diagnostics
Popis výsledku v původním jazyce
Paper tests are very cheap and fast diagnostic tools for self-testing in a wide range of health problems. Thus, the diagnostics of tumor development is of a great medical and socio-economic significance. Malignant prostate cancers are the most common malignancy in men. Procedures have been developed to diagnose this disease based on the monitoring of tumor marker molecules. Most commonly, PSA and fPSA are used. Although these tumor markers are significantly increased, the cancer at the biopsy is not always confirmed. Thus, the finding of other marker molecules is urgently needed. Recent studies have shown that changes in content of the amino acid sarcosine are associated with prostate tumors. Polyclonal chicken antibodies against sarcosine (AntiSar) were prepared. AntiSar antibodies were labeled with gold nanoparticles Au20 (size 20-30 nm, zeta potential - 38 mV) and CdTe QDs (emission 530 green QDs and 650 nm yellow QDs). Dot blot and flow lateral chromatography were used to develop a newly designed sarcosin detection procedure. The aggregation or fluorescence intensities were evaluated by newly designed software. Sarcosine was analyzed in a concentration range (0-150 μM) in PBS, arteficial urine and urine sample buffer. The calibration curves obtained in the concentration range (0-12 μM) were strictly linear (R2 = 0.99) with a relative error of 10%. Using the proposed methods sarcosine concentrations as low as 250-500 nM were analyzed. Moreover, the results obtained show a higher sensitivity (by 20-40%) of sarcosine detection using QDs in comparison with using gold nanoparticles.
Název v anglickém jazyce
Antibodies Modified by Gold Nanoparticles or Quantum Dots For Specific Detection of Sarcosine on The Membrane: Use in Rapid Diagnostics
Popis výsledku anglicky
Paper tests are very cheap and fast diagnostic tools for self-testing in a wide range of health problems. Thus, the diagnostics of tumor development is of a great medical and socio-economic significance. Malignant prostate cancers are the most common malignancy in men. Procedures have been developed to diagnose this disease based on the monitoring of tumor marker molecules. Most commonly, PSA and fPSA are used. Although these tumor markers are significantly increased, the cancer at the biopsy is not always confirmed. Thus, the finding of other marker molecules is urgently needed. Recent studies have shown that changes in content of the amino acid sarcosine are associated with prostate tumors. Polyclonal chicken antibodies against sarcosine (AntiSar) were prepared. AntiSar antibodies were labeled with gold nanoparticles Au20 (size 20-30 nm, zeta potential - 38 mV) and CdTe QDs (emission 530 green QDs and 650 nm yellow QDs). Dot blot and flow lateral chromatography were used to develop a newly designed sarcosin detection procedure. The aggregation or fluorescence intensities were evaluated by newly designed software. Sarcosine was analyzed in a concentration range (0-150 μM) in PBS, arteficial urine and urine sample buffer. The calibration curves obtained in the concentration range (0-12 μM) were strictly linear (R2 = 0.99) with a relative error of 10%. Using the proposed methods sarcosine concentrations as low as 250-500 nM were analyzed. Moreover, the results obtained show a higher sensitivity (by 20-40%) of sarcosine detection using QDs in comparison with using gold nanoparticles.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21002 - Nano-processes (applications on nano-scale); (biomaterials to be 2.9)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Nanocon 2017
ISBN
978-80-87294-81-9
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
6
Strana od-do
517-523
Název nakladatele
Tanger s.r.o.
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
18. 10. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000452823300085