Detekce bioafinitních komplexů v mikrokanále fluorescenčními technikami
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F08%3A00020219" target="_blank" >RIV/60461373:22340/08:00020219 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of bioaffinity complexes in microchannels by fluorescence techniques.
Popis výsledku v původním jazyce
This work deals with multichannel microfluidic systems intended for bioapplications, particularly for medical diagnostics. Microfluidic systems consist of several parallel channels with small characteristic dimensions (10-100 ?m). These devices are fabricated from polystyrene (PS) and polydimethylsiloxane (PDMS) by a combination of microfabrication techniques ? UV photolithography, micromilling, thermal bonding, galvanic metallization, casting etc. In the experiments, the biological receptor is immobilized on the microchannel walls by a passive sorption. The blocking reagent 1 % BSA is used to cover empty regions on the walls. Then, aqueous solutions of ligands and detection reagents with a fluorescent marker are subsequently introduced in the channels. Finally, a solution of a detergent is used to break nonspecific bonds among the biomolecules. The main advantage of the used experimental arrangement is that the reaction time of each reaction step in this experimental arrangement is no
Název v anglickém jazyce
Detection of bioaffinity complexes in microchannels by fluorescence techniques.
Popis výsledku anglicky
This work deals with multichannel microfluidic systems intended for bioapplications, particularly for medical diagnostics. Microfluidic systems consist of several parallel channels with small characteristic dimensions (10-100 ?m). These devices are fabricated from polystyrene (PS) and polydimethylsiloxane (PDMS) by a combination of microfabrication techniques ? UV photolithography, micromilling, thermal bonding, galvanic metallization, casting etc. In the experiments, the biological receptor is immobilized on the microchannel walls by a passive sorption. The blocking reagent 1 % BSA is used to cover empty regions on the walls. Then, aqueous solutions of ligands and detection reagents with a fluorescent marker are subsequently introduced in the channels. Finally, a solution of a detergent is used to break nonspecific bonds among the biomolecules. The main advantage of the used experimental arrangement is that the reaction time of each reaction step in this experimental arrangement is no
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CD-ROM of Full Texts CHISA 2008
ISBN
978-80-02-02047-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Process Engineering Publisher
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
24. 8. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—