Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F09%3A00022531" target="_blank" >RIV/60461373:22340/09:00022531 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers
Popis výsledku v původním jazyce
Cross-calibration of dual-stage detector is a very important procedure that enables extension of a dynamic range of an inductively coupled plasma mass spectrometer. A calibration procedure based on the measurements of the intensities of argon plasma ionsand matrix ions protects the spectrometer against contaminations; however, it can lead to the misinterpretation of the measured data, especially in the high atomic mass region. Calibration procedures based on the measurement of the intensities of argonplasma and matrix ions and of metal ions were mutually compared. Exemplary determination results for manganese (0-200 ng/mL), cesium (0-50 ng/mL) and lead (0-100 ng/mL) showed that only the dual detector calibration based on metal ions intensities measurements gives linear calibration plots.
Název v anglickém jazyce
Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers
Popis výsledku anglicky
Cross-calibration of dual-stage detector is a very important procedure that enables extension of a dynamic range of an inductively coupled plasma mass spectrometer. A calibration procedure based on the measurements of the intensities of argon plasma ionsand matrix ions protects the spectrometer against contaminations; however, it can lead to the misinterpretation of the measured data, especially in the high atomic mass region. Calibration procedures based on the measurement of the intensities of argonplasma and matrix ions and of metal ions were mutually compared. Exemplary determination results for manganese (0-200 ng/mL), cesium (0-50 ng/mL) and lead (0-100 ng/mL) showed that only the dual detector calibration based on metal ions intensities measurements gives linear calibration plots.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemia Analityczna
ISSN
0009-2223
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—