Profile method? for the measurement of kLa and kVa in distillation column. Validation of ratebased distillation models using concentration profiles measured along the column
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F10%3A00023527" target="_blank" >RIV/60461373:22340/10:00023527 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Profile method? for the measurement of kLa and kVa in distillation column. Validation of ratebased distillation models using concentration profiles measured along the column
Popis výsledku v původním jazyce
The "profile method" enables the determination of vapor- and liquid-side volumetric mass transfer coefficients kVa and kLa by comparing the concentration profiles measured in both phases in a distillation column with the simulated profiles. The method isbased on the fact that the shape of the concentration profiles along the column depend significantly on the distribution of the mass transfer resistance between the liquid and the vapor phases. This makes possible the measuring of kLa and kVa directly in the distillation columns, in the same manner is possible in absorption columns, and therefore to validate the distillation models more conclusively than by means of comparing the experimental and calculated HETP-values. The coefficients were measured on structured packing Mellapak250Y. A small axial mixing of phases on this type of packing enables the use of a plug flow model for both phases. Three distillation systems, methanol ethanol, ethanol-propanol and methanol-propanol, were use
Název v anglickém jazyce
Profile method? for the measurement of kLa and kVa in distillation column. Validation of ratebased distillation models using concentration profiles measured along the column
Popis výsledku anglicky
The "profile method" enables the determination of vapor- and liquid-side volumetric mass transfer coefficients kVa and kLa by comparing the concentration profiles measured in both phases in a distillation column with the simulated profiles. The method isbased on the fact that the shape of the concentration profiles along the column depend significantly on the distribution of the mass transfer resistance between the liquid and the vapor phases. This makes possible the measuring of kLa and kVa directly in the distillation columns, in the same manner is possible in absorption columns, and therefore to validate the distillation models more conclusively than by means of comparing the experimental and calculated HETP-values. The coefficients were measured on structured packing Mellapak250Y. A small axial mixing of phases on this type of packing enables the use of a plug flow model for both phases. Three distillation systems, methanol ethanol, ethanol-propanol and methanol-propanol, were use
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ind.Eng.Chem., Res.
ISSN
0888-5885
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
—
Kód UT WoS článku
000277041700039
EID výsledku v databázi Scopus
—