Mass transfer measurement in the ejector by new steady-state method using the chemical removal of oxygen
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F15%3A43900380" target="_blank" >RIV/60461373:22340/15:43900380 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mass transfer measurement in the ejector by new steady-state method using the chemical removal of oxygen
Popis výsledku v původním jazyce
Ejector with volumetric mass transfer coefficients (kLa) about 10 s-1 is interesting alternative for gas-liquid operation. However, because reliable data describing the mass transfer in ejector are missing, design of ejector for the mass transfer operations is difficult. Detailed investigation of mass transfer in ejector is limited by methods of determination kLa. Suitable method which can be applied for mass transfer measurement in ejector is steady-state physical absorption of oxygen, but this methodrequires sophisticated apparatus and that is not convenient for serial experiments. Chemical removal of oxygen seems like a promising alternative. Chemical method is relatively simple in terms of required additional equipment. Method of chemical removalof oxygen was tested in ejector loop. Verification of this method was done by comparison of values kLa obtained by oxygen scavenging method with values of kLa obtained by method of physical desorption when the desorption column was used f
Název v anglickém jazyce
Mass transfer measurement in the ejector by new steady-state method using the chemical removal of oxygen
Popis výsledku anglicky
Ejector with volumetric mass transfer coefficients (kLa) about 10 s-1 is interesting alternative for gas-liquid operation. However, because reliable data describing the mass transfer in ejector are missing, design of ejector for the mass transfer operations is difficult. Detailed investigation of mass transfer in ejector is limited by methods of determination kLa. Suitable method which can be applied for mass transfer measurement in ejector is steady-state physical absorption of oxygen, but this methodrequires sophisticated apparatus and that is not convenient for serial experiments. Chemical removal of oxygen seems like a promising alternative. Chemical method is relatively simple in terms of required additional equipment. Method of chemical removalof oxygen was tested in ejector loop. Verification of this method was done by comparison of values kLa obtained by oxygen scavenging method with values of kLa obtained by method of physical desorption when the desorption column was used f
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP106%2F11%2F1865" target="_blank" >GAP106/11/1865: Nová koncenpce návrhu reaktorů s ejektorovým distributorem plynu. Metodika a získání základních dat.</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 42nd International Conference of Slovak Society of Chemical Engineering
ISBN
978-80-89475-14-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
402-409
Název nakladatele
J. Markoš, V. Štefuca
Místo vydání
Bratislava
Místo konání akce
Tatranské Matliare
Datum konání akce
25. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—