Marginal bone response of submerged and nonsubmerged osteoconductive alkali-etched implants in thick and thin biotypes: A 2-year clinical follow-up study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F19%3A43918439" target="_blank" >RIV/60461373:22340/19:43918439 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.lasak.cz/wp-content/uploads/2019/10/Jomi_34_5_Novak_p1184.pdf" target="_blank" >https://www.lasak.cz/wp-content/uploads/2019/10/Jomi_34_5_Novak_p1184.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.11607/jomi.7399" target="_blank" >10.11607/jomi.7399</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Marginal bone response of submerged and nonsubmerged osteoconductive alkali-etched implants in thick and thin biotypes: A 2-year clinical follow-up study
Popis výsledku v původním jazyce
Purpose: This follow-up study evaluated the implant success rate and marginal bone response of submerged and nonsubmerged osteoconductive two-piece implants with a moderately rough implant neck in thick and thin gingival biotypes. Materials and Methods: The stability of the hard tissue surrounding the implants was evaluated, based on clinical and radiographic examinations performed after implant placement and every follow-up thereafter. The clinical data were processed via linear mixed-effects model statistics at the patient level. Results: Forty-three edentulous and partially edentulous patients were treated with a total of 97 implants with an osteoconductive surface. After 2 years in function, all the implants and dental prostheses reached a 100% success rate according to predefined criteria. Taking implantation as a baseline, the mean change in the marginal bone level (ΔMBLp) after 2 years in function was -0.36 mm (SD: 0.55), and bone resorption higher than 1 mm and less than 2.5 mm was observed for seven implants. Taking dental prosthesis placement as a baseline, the ΔMBLp after 2 years of loading was -0.13 mm (SD: 0.39), and bone resorption higher than 1 mm and less than 2.0 mm was observed only for two implants. Statistically significant differences in mean marginal bone loss were observed in the gingival biotype (P = .006) and submersion (P < .05). Their influence on the dynamics of peri-implant bone loss during the process of biologic width restoration was analyzed. Conclusion: This study demonstrated the high stability of peri-implant hard tissue and the 100% success rate of the implant system with a moderately rough neck. The biotype and implant submersion were evaluated as factors having a significant influence on marginal bone loss.
Název v anglickém jazyce
Marginal bone response of submerged and nonsubmerged osteoconductive alkali-etched implants in thick and thin biotypes: A 2-year clinical follow-up study
Popis výsledku anglicky
Purpose: This follow-up study evaluated the implant success rate and marginal bone response of submerged and nonsubmerged osteoconductive two-piece implants with a moderately rough implant neck in thick and thin gingival biotypes. Materials and Methods: The stability of the hard tissue surrounding the implants was evaluated, based on clinical and radiographic examinations performed after implant placement and every follow-up thereafter. The clinical data were processed via linear mixed-effects model statistics at the patient level. Results: Forty-three edentulous and partially edentulous patients were treated with a total of 97 implants with an osteoconductive surface. After 2 years in function, all the implants and dental prostheses reached a 100% success rate according to predefined criteria. Taking implantation as a baseline, the mean change in the marginal bone level (ΔMBLp) after 2 years in function was -0.36 mm (SD: 0.55), and bone resorption higher than 1 mm and less than 2.5 mm was observed for seven implants. Taking dental prosthesis placement as a baseline, the ΔMBLp after 2 years of loading was -0.13 mm (SD: 0.39), and bone resorption higher than 1 mm and less than 2.0 mm was observed only for two implants. Statistically significant differences in mean marginal bone loss were observed in the gingival biotype (P = .006) and submersion (P < .05). Their influence on the dynamics of peri-implant bone loss during the process of biologic width restoration was analyzed. Conclusion: This study demonstrated the high stability of peri-implant hard tissue and the 100% success rate of the implant system with a moderately rough neck. The biotype and implant submersion were evaluated as factors having a significant influence on marginal bone loss.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
<a href="/cs/project/TE01020390" target="_blank" >TE01020390: Centrum vývoje moderních kovových biomateriálů pro lékařské implantáty</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Oral and Maxilofacial implants
ISSN
0882-2786
e-ISSN
1942-4434
Svazek periodika
34
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
1180-1190
Kód UT WoS článku
000486386700020
EID výsledku v databázi Scopus
2-s2.0-85072508694