Development of methodology for the study of API sensitivity to hydrolytic degradations at different pH conditions in solid-state
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F21%3A43922043" target="_blank" >RIV/60461373:22340/21:43922043 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s11696-021-01630-x" target="_blank" >https://link.springer.com/article/10.1007/s11696-021-01630-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11696-021-01630-x" target="_blank" >10.1007/s11696-021-01630-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of methodology for the study of API sensitivity to hydrolytic degradations at different pH conditions in solid-state
Popis výsledku v původním jazyce
The present study is focused on the development of methodology for testing drug sensitivity to hydrolytic degradation in different pH conditions in solid-state. To test hydrolytic degradations in solid-state, methodology using different silica and silicates with varying pH (3.9-9.7) was developed. Hydrolytic degradations in varying pH conditions of two drugs, bisoprolol and sofosbuvir were examined in solution as well as in solid-state using HPLC. Impurity profiles in solid-state and in solution differed for sofosbuvir. A bisoprolol hydrolytic curve measured in solid-state showed different dependence between pH and degradation than in solution. The main difference between testing the effects of pH on API stability in solution and in solid-state is that different degradation mechanisms are taking place. It was confirmed that degradation mechanisms observed in solid-state testing are much closer to degradation mechanisms observed for solid dosage forms than degradation mechanism observed while using standard method of testing in solution.
Název v anglickém jazyce
Development of methodology for the study of API sensitivity to hydrolytic degradations at different pH conditions in solid-state
Popis výsledku anglicky
The present study is focused on the development of methodology for testing drug sensitivity to hydrolytic degradation in different pH conditions in solid-state. To test hydrolytic degradations in solid-state, methodology using different silica and silicates with varying pH (3.9-9.7) was developed. Hydrolytic degradations in varying pH conditions of two drugs, bisoprolol and sofosbuvir were examined in solution as well as in solid-state using HPLC. Impurity profiles in solid-state and in solution differed for sofosbuvir. A bisoprolol hydrolytic curve measured in solid-state showed different dependence between pH and degradation than in solution. The main difference between testing the effects of pH on API stability in solution and in solid-state is that different degradation mechanisms are taking place. It was confirmed that degradation mechanisms observed in solid-state testing are much closer to degradation mechanisms observed for solid dosage forms than degradation mechanism observed while using standard method of testing in solution.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
0366-6352
e-ISSN
—
Svazek periodika
75
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
9
Strana od-do
5739-5747
Kód UT WoS článku
000668046200001