An LBNP examination method was developed for the pilot applicants' pre-selection with low level of +Gz tolerance. Results of the LBNP test depend on exposure time duration. Ending of the LBNP exposure is determined by LBNP stop criteria rules. LBNP stopcriteria have been stepwise experimentally elaborated. Blood pressure ranks among the essential physiological data measured during LBNP examinations. Blood pressure responds very sensitively to the LBNP load, which stands for a significant parameter reflecting the cardiovascular regulation level in the orthostatic load. Physiological response of the organism during an LBNP examination is rapid, and therefore it proved to be advantageous to measure the continuous finger blood pressure by a Portapres device. The rapid blood pressure decrease comes into being very shortly after the LBNP exposure at the substandard result group. The worst combination is when systolic blood pressure value and pulse pressure decrease are followed by rapid hea
Název v anglickém jazyce
Pilots? cardiovascular response in LBNP exposure
Popis výsledku anglicky
An LBNP examination method was developed for the pilot applicants' pre-selection with low level of +Gz tolerance. Results of the LBNP test depend on exposure time duration. Ending of the LBNP exposure is determined by LBNP stop criteria rules. LBNP stopcriteria have been stepwise experimentally elaborated. Blood pressure ranks among the essential physiological data measured during LBNP examinations. Blood pressure responds very sensitively to the LBNP load, which stands for a significant parameter reflecting the cardiovascular regulation level in the orthostatic load. Physiological response of the organism during an LBNP examination is rapid, and therefore it proved to be advantageous to measure the continuous finger blood pressure by a Portapres device. The rapid blood pressure decrease comes into being very shortly after the LBNP exposure at the substandard result group. The worst combination is when systolic blood pressure value and pulse pressure decrease are followed by rapid hea
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Federation for Medical and Biological Engineering, ICBME 2005
ISBN
981-05-4572-X
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
ICBME 2005 & IFMBE,
Místo vydání
Singapore
Místo konání akce
Singapore
Datum konání akce
1. 1. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—