Simulace Push-Pull efektu pomocí LBNP zařízení
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61382981%3A_____%2F08%3AULZHA003" target="_blank" >RIV/61382981:_____/08:ULZHA003 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Push-Pull Effect Simulation by the LBNP Device
Popis výsledku v původním jazyce
The LBNP examination consists of two stages. The first stage represents the Push Pull simulation the second stage corresponds to the standard LBNP exposure. Push-Pull effect is simulated by means of tilting LBNP device backwards to the -43° HDT (head down tilt) position. There is atmospheric pressure in the LBNP chamber. This first step corresponds to the plateau of microgravity. +Gz load is created by the rapid LBNP exposition accompanied with a rapid return of the LBNP device to the vertical position.Negative pressure level has the value of ?70 mmHg and this value is achieved in one second. The return of the device to the vertical position is accomplished also very rapidly, namely in two seconds. The second stage is accomplished again with one stepexposure to the negative pressure level of -70 mmHg with achievement of this value again in one second. Pilots are examined in the sitting position. LBNP exposition is also used as a method of drill in anti-g maneuvers.
Název v anglickém jazyce
Push-Pull Effect Simulation by the LBNP Device
Popis výsledku anglicky
The LBNP examination consists of two stages. The first stage represents the Push Pull simulation the second stage corresponds to the standard LBNP exposure. Push-Pull effect is simulated by means of tilting LBNP device backwards to the -43° HDT (head down tilt) position. There is atmospheric pressure in the LBNP chamber. This first step corresponds to the plateau of microgravity. +Gz load is created by the rapid LBNP exposition accompanied with a rapid return of the LBNP device to the vertical position.Negative pressure level has the value of ?70 mmHg and this value is achieved in one second. The return of the device to the vertical position is accomplished also very rapidly, namely in two seconds. The second stage is accomplished again with one stepexposure to the negative pressure level of -70 mmHg with achievement of this value again in one second. Pilots are examined in the sitting position. LBNP exposition is also used as a method of drill in anti-g maneuvers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the ICBME2008 ? 13th International Conference on Biomedical Engineering
ISBN
978-3-540-92840-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Springer Berlin Heidelberg New York
Místo vydání
New York
Místo konání akce
Singapore
Datum konání akce
1. 1. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—