Změny reologických vlastností kolenního kloubu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F07%3A08" target="_blank" >RIV/61383082:_____/07:08 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The changes of the rheological properties of the knee joint in the separate cause
Popis výsledku v původním jazyce
The ultimate objective of our effort is to offer an accessible alternative for probing and objectification of the physiological condition of human joints and their changes. In this phase we are focusing on the knee joint, nevertheless the measurement principle would have a universal application. For this purpose we are using a special apparatus of an original construction acquiring the rheological properties of the knee-joint by the non-invasive method in vivo, therefore with zero stress on the organism. The principle of this method is based in the divulgence of the secrets of the hysteresis curve of the resistance torque in relation to the knee-flexion angle. The measurements of the complex living knee mechanical properties make it difficult for us toachieve at least a few valid results. It is not possible to apply our integrated metering on the simple mathematical simulation for high presence of articulated tissues.
Název v anglickém jazyce
The changes of the rheological properties of the knee joint in the separate cause
Popis výsledku anglicky
The ultimate objective of our effort is to offer an accessible alternative for probing and objectification of the physiological condition of human joints and their changes. In this phase we are focusing on the knee joint, nevertheless the measurement principle would have a universal application. For this purpose we are using a special apparatus of an original construction acquiring the rheological properties of the knee-joint by the non-invasive method in vivo, therefore with zero stress on the organism. The principle of this method is based in the divulgence of the secrets of the hysteresis curve of the resistance torque in relation to the knee-flexion angle. The measurements of the complex living knee mechanical properties make it difficult for us toachieve at least a few valid results. It is not possible to apply our integrated metering on the simple mathematical simulation for high presence of articulated tissues.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OPUVN20070002" target="_blank" >OPUVN20070002: APARÁT - Epidemiologie onemocnění pohybového aparátu, metodika prevence, diagnostiky a léčby</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomechanics
ISSN
0021-9290
e-ISSN
—
Svazek periodika
2007
Číslo periodika v rámci svazku
40
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
1
Strana od-do
459
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—