Bioreometrie kolenního kloubu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F07%3A09" target="_blank" >RIV/61383082:_____/07:09 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biorheometry of the knee-joint
Popis výsledku v původním jazyce
The subject of the work is the experimental in vivo measurement of the knee-joint rheology. It has been performed on the measuring equipment called biorheometer. We hope that biorheometer may be useful toll of the knee-joint investigation as possibilities of the clinical functional examination of the movement system in the myoskeletal medicine are limited. Biorheometry measures in vivo the overall mechanical impedance of a knee-joint. The mechanical impedance is the ratio of complex stress to complex strain. This ratio is measured by the biorheometer at fixed frequency and the corresponding ?hysteresis-curve? is obtained. The ?hysteresis-curve? gives some insight in the viscoelastic properties of the knee-joint. We shall call this ?hysteresis-curve? abiorheogram. We think that biorheometry is a very adequate method for monitoring this rehabilitation process as it measures the function of the knee-joint and not only the structural pathology of it as is done by the usual visual- imaging
Název v anglickém jazyce
Biorheometry of the knee-joint
Popis výsledku anglicky
The subject of the work is the experimental in vivo measurement of the knee-joint rheology. It has been performed on the measuring equipment called biorheometer. We hope that biorheometer may be useful toll of the knee-joint investigation as possibilities of the clinical functional examination of the movement system in the myoskeletal medicine are limited. Biorheometry measures in vivo the overall mechanical impedance of a knee-joint. The mechanical impedance is the ratio of complex stress to complex strain. This ratio is measured by the biorheometer at fixed frequency and the corresponding ?hysteresis-curve? is obtained. The ?hysteresis-curve? gives some insight in the viscoelastic properties of the knee-joint. We shall call this ?hysteresis-curve? abiorheogram. We think that biorheometry is a very adequate method for monitoring this rehabilitation process as it measures the function of the knee-joint and not only the structural pathology of it as is done by the usual visual- imaging
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OPUVN20070002" target="_blank" >OPUVN20070002: APARÁT - Epidemiologie onemocnění pohybového aparátu, metodika prevence, diagnostiky a léčby</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomechanics
ISSN
0021-9290
e-ISSN
—
Svazek periodika
2007
Číslo periodika v rámci svazku
40
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
1
Strana od-do
550
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—