A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F25%3A00001541" target="_blank" >RIV/61383082:_____/25:00001541 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/25:00385956 RIV/61988987:17110/25:A2603DM4
Výsledek na webu
<a href="https://pubmed.ncbi.nlm.nih.gov/40526268/" target="_blank" >https://pubmed.ncbi.nlm.nih.gov/40526268/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s41205-025-00271-0" target="_blank" >10.1186/s41205-025-00271-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography
Popis výsledku v původním jazyce
The use of 3D-printed hemodynamic phantom of a stenotic carotid artery has not been extensively investigated. Our study aims to address this gap by exploring the correlation between CTA and flow parameters in hemodynamic phantom. Methods: Patients with carotid stenosis were included in a prospective study. A realistic phantoms of carotid artery stenoses were 3D-printed based on CT angiography. Stenosis severity and hemodynamic flow parameters in the phantom evaluated using duplex sonography were correlated with CTA. The primary outcome was to compare the evaluation of the percentage of stenosis based on the measurement of diameter reduction and area reduction of the carotid artery among CTA, a 3D model constructed from CTA data, and ultrasound measurement of stenosis percentage within the 3D printed phantom. The secondary outcome was to determine whether the percentage of stenosis measured by ultrasound in B-mode or ultrasound-measured flow velocities (PSV, EDV) better correlates with the stenosis percentage derived from CTA and the phantom. Results: The study included 95 subjects (average age 71 years, 75% male) with carotid stenosis, 39% were symptomatic. Significant correlations were found between ultrasound B-Mode findings on the phantom and CTA, with the strongest correlations for area reduction (Spearman r = 0.615, p < 0.0001) and diameter reduction (Spearman r = 0.465, p < 0.0001). The most robust correlation between PSV and EDV in stenosis and the percentage of stenosis was identified between PSV in stenosis and the percentage of stenosis by diameter reduction, as evaluated through ultrasound. The Spearman correlation coefficient revealed a relatively strong correlation, with a value of r = 0.444 (p < 0.0001), and the Kendall Tau correlation coefficient also demonstrated significance, with a value of r = 0.302 (p < 0.0001). Conclusions: A significant correlation between CTA and duplex sonography measurements on the carotid phantom was demostrated, suggesting the potential utilization of the phantom in testing hemodynamic parameters of carotid stenosis.
Název v anglickém jazyce
A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography
Popis výsledku anglicky
The use of 3D-printed hemodynamic phantom of a stenotic carotid artery has not been extensively investigated. Our study aims to address this gap by exploring the correlation between CTA and flow parameters in hemodynamic phantom. Methods: Patients with carotid stenosis were included in a prospective study. A realistic phantoms of carotid artery stenoses were 3D-printed based on CT angiography. Stenosis severity and hemodynamic flow parameters in the phantom evaluated using duplex sonography were correlated with CTA. The primary outcome was to compare the evaluation of the percentage of stenosis based on the measurement of diameter reduction and area reduction of the carotid artery among CTA, a 3D model constructed from CTA data, and ultrasound measurement of stenosis percentage within the 3D printed phantom. The secondary outcome was to determine whether the percentage of stenosis measured by ultrasound in B-mode or ultrasound-measured flow velocities (PSV, EDV) better correlates with the stenosis percentage derived from CTA and the phantom. Results: The study included 95 subjects (average age 71 years, 75% male) with carotid stenosis, 39% were symptomatic. Significant correlations were found between ultrasound B-Mode findings on the phantom and CTA, with the strongest correlations for area reduction (Spearman r = 0.615, p < 0.0001) and diameter reduction (Spearman r = 0.465, p < 0.0001). The most robust correlation between PSV and EDV in stenosis and the percentage of stenosis was identified between PSV in stenosis and the percentage of stenosis by diameter reduction, as evaluated through ultrasound. The Spearman correlation coefficient revealed a relatively strong correlation, with a value of r = 0.444 (p < 0.0001), and the Kendall Tau correlation coefficient also demonstrated significance, with a value of r = 0.302 (p < 0.0001). Conclusions: A significant correlation between CTA and duplex sonography measurements on the carotid phantom was demostrated, suggesting the potential utilization of the phantom in testing hemodynamic parameters of carotid stenosis.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/NU22-04-00389" target="_blank" >NU22-04-00389: Vliv metabolomu aterosklerotického plátu v karotidě na jeho embolizační potenciál</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
3D Printing in Medicine
ISSN
2365-6271
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
1-12
Kód UT WoS článku
001510495600001
EID výsledku v databázi Scopus
2-s2.0-105008227673