Hmotnostní spektrometrie v proudové trubici s vybranými ionty (SIFT-MS) pro průběžnou analýzu stopových plynů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F05%3A00000805" target="_blank" >RIV/61388955:_____/05:00000805 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Selected ion flow tube mass spectrometry (sift-MS) for on-line trace gas analysis
Popis výsledku v původním jazyce
Selected ion flow tube mass spectrometry (SIFT-MS) is a new analytical technique for the real-time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H3O+, NO+, and O2+ precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream massspectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to ppb levels, obviating sample collection and calibration. Flowing afterglow mass spectrometry (FA-MS) isbriefly described, which allows on-line quantification of deuterium in breath water vapor.
Název v anglickém jazyce
Selected ion flow tube mass spectrometry (sift-MS) for on-line trace gas analysis
Popis výsledku anglicky
Selected ion flow tube mass spectrometry (SIFT-MS) is a new analytical technique for the real-time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H3O+, NO+, and O2+ precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream massspectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to ppb levels, obviating sample collection and calibration. Flowing afterglow mass spectrometry (FA-MS) isbriefly described, which allows on-line quantification of deuterium in breath water vapor.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Mass Spectrometry Reviews
ISSN
0277-7037
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
40
Strana od-do
661-700
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—