Vliv konvekce na transport difúzí a prosívání vody a malých rozpuštěných molekul skrze periotoneální membránu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F05%3A00021156" target="_blank" >RIV/61388955:_____/05:00021156 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of convection on the diffusive transport and sieving of water and small solutes across the peritoneal membrane
Popis výsledku v původním jazyce
The three-pore model of peritoneal membrane physiology predicts sieving of small solutes as a result of the presence of a water-exclusive pathway. The purpose of this study was to measure the diffusive and convective components of small solute transport,including water, under differing convection. Triplicate studies were performed in eight stable individuals using 2-L exchanges of bicarbonate buffered 1.36 or 3.86% glucose and icodextrin. Diffusion of water was estimated by establishing an artificial gradient of deuterated water (HDO) between blood/body water and the dialysate. (125)RISA (radio-iodinated serum albumin) was used as an intraperitoneal volume marker to determine the net ultrafiltration and reabsorption of fluid. The mass transfer area coefficient (MTAC) for HDO and solutes was estimated using the Garred and Waniewski equations.
Název v anglickém jazyce
Influence of convection on the diffusive transport and sieving of water and small solutes across the peritoneal membrane
Popis výsledku anglicky
The three-pore model of peritoneal membrane physiology predicts sieving of small solutes as a result of the presence of a water-exclusive pathway. The purpose of this study was to measure the diffusive and convective components of small solute transport,including water, under differing convection. Triplicate studies were performed in eight stable individuals using 2-L exchanges of bicarbonate buffered 1.36 or 3.86% glucose and icodextrin. Diffusion of water was estimated by establishing an artificial gradient of deuterated water (HDO) between blood/body water and the dialysate. (125)RISA (radio-iodinated serum albumin) was used as an intraperitoneal volume marker to determine the net ultrafiltration and reabsorption of fluid. The mass transfer area coefficient (MTAC) for HDO and solutes was estimated using the Garred and Waniewski equations.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F03%2F0827" target="_blank" >GA202/03/0827: Studium elementárních procesů v nízkoteplotním a technologicky orientovaném plazmatu a vývoj relevantních diagnostických metod</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the American Society of Nephrology
ISSN
1046-6673
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
437-443
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—