Odhad limitů iontově selektivních elektrod: Metoda stanovení potenciálového rozpětí, dynamického rozsahu a koeficientů selektivity kationtových selektivních elektrod s neutrálním nosičem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F06%3A00032431" target="_blank" >RIV/61388955:_____/06:00032431 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
How to assess the limits of ion-selective electrodes: Method for the determination of the ultimate span, response range, and selectivity coefficients of neutral carrier-based cation selective electrodes
Popis výsledku v původním jazyce
The span and range of an ion-selective electrode (ISE) has been identified by IUPAC as a potential or activity difference between the upper and lower detection limits of the electrode. Once the span is known, the ultimately attainable detection limit ofthe ISE can be calculated using its theoretical response slope. In this paper, we propose an original method for the determination of the ultimate span and response range of ISEs. The simple measurement of span is recommended to aid the fast screening ofnovel ionophores and help to focus optimization processes to the most promising candidates. The measurement of span is combined with a generally applicable procedure for the determination of the three seminal parameters of ISEs: the response slope, theultimate selectivity coefficients, and detection limit. In the proposed procedure, following the span measurement, two subsequent exponential dilution experiments are completed in which the responses of the electrode ...
Název v anglickém jazyce
How to assess the limits of ion-selective electrodes: Method for the determination of the ultimate span, response range, and selectivity coefficients of neutral carrier-based cation selective electrodes
Popis výsledku anglicky
The span and range of an ion-selective electrode (ISE) has been identified by IUPAC as a potential or activity difference between the upper and lower detection limits of the electrode. Once the span is known, the ultimately attainable detection limit ofthe ISE can be calculated using its theoretical response slope. In this paper, we propose an original method for the determination of the ultimate span and response range of ISEs. The simple measurement of span is recommended to aid the fast screening ofnovel ionophores and help to focus optimization processes to the most promising candidates. The measurement of span is combined with a generally applicable procedure for the determination of the three seminal parameters of ISEs: the response slope, theultimate selectivity coefficients, and detection limit. In the proposed procedure, following the span measurement, two subsequent exponential dilution experiments are completed in which the responses of the electrode ...
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Chemistry
ISSN
0003-2700
e-ISSN
—
Svazek periodika
78
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
942-950
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—