Selected Ion Flow Tube (SIFT) Applications in Mass Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F17%3A00464687" target="_blank" >RIV/61388955:_____/17:00464687 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/B978-0-12-409547-2.05253-7" target="_blank" >http://dx.doi.org/10.1016/B978-0-12-409547-2.05253-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/B978-0-12-409547-2.05253-7" target="_blank" >10.1016/B978-0-12-409547-2.05253-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Selected Ion Flow Tube (SIFT) Applications in Mass Spectrometry
Popis výsledku v původním jazyce
The first version of this article published in 1999 in Encyclopedianof Spectroscopy and Spectrometry, under the title “SIFTnapplications in mass spectrometry”, focused on the selectednion flow tube, SIFT, technique that was primarily developednand used for the study of the kinetics of ion-molecule reactionsnat thermal energies. The basic physics and ion chemistry onnwhich the SIFT technique relies were described by the ratencoefficients and product ion distributions for ion-molecule reactions,nboth of intrinsic fundamental interest and also of importancento the understanding of the ionic reactions that dominatenthe gas phase ion chemistry of the terrestrial atmosphere andnof the gas clouds that pervade the interstellar medium, asnreviewed in.1 In the interim, this science has moved on andnthe SIFT technique is now not so much used for fundamentalnion chemistry studies, although it still has a valuable role in thenlatest research in understanding the chemistry occurring innthe atmospheres of the satellites of the outer planets,2 but nownit is mostly used to underpin the new analytical method bynwhich ambient analysis of air and exhaled breath can be accomplished,nwhich we call selected ion flow tube mass spectrometry,nSIFT-MS, that is the focus of this updated article.
Název v anglickém jazyce
Selected Ion Flow Tube (SIFT) Applications in Mass Spectrometry
Popis výsledku anglicky
The first version of this article published in 1999 in Encyclopedianof Spectroscopy and Spectrometry, under the title “SIFTnapplications in mass spectrometry”, focused on the selectednion flow tube, SIFT, technique that was primarily developednand used for the study of the kinetics of ion-molecule reactionsnat thermal energies. The basic physics and ion chemistry onnwhich the SIFT technique relies were described by the ratencoefficients and product ion distributions for ion-molecule reactions,nboth of intrinsic fundamental interest and also of importancento the understanding of the ionic reactions that dominatenthe gas phase ion chemistry of the terrestrial atmosphere andnof the gas clouds that pervade the interstellar medium, asnreviewed in.1 In the interim, this science has moved on andnthe SIFT technique is now not so much used for fundamentalnion chemistry studies, although it still has a valuable role in thenlatest research in understanding the chemistry occurring innthe atmospheres of the satellites of the outer planets,2 but nownit is mostly used to underpin the new analytical method bynwhich ambient analysis of air and exhaled breath can be accomplished,nwhich we call selected ion flow tube mass spectrometry,nSIFT-MS, that is the focus of this updated article.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Encyclopedia of Spectroscopy and Spectrometry
ISBN
978-0128032244
Počet stran výsledku
13
Strana od-do
56-68
Počet stran knihy
3584
Název nakladatele
Academic Press
Místo vydání
Oxford
Kód UT WoS kapitoly
—