Voltammetric Determination of Tumor Biomarkers for Neuroblastoma (Homovanillic Acid, Vanillylmandelic Acid, and 5-Hydroxyindole-3-acetic Acid) at Screen-printed Carbon Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F17%3A00466719" target="_blank" >RIV/61388955:_____/17:00466719 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/17:10362353
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201600534" target="_blank" >http://dx.doi.org/10.1002/elan.201600534</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201600534" target="_blank" >10.1002/elan.201600534</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Tumor Biomarkers for Neuroblastoma (Homovanillic Acid, Vanillylmandelic Acid, and 5-Hydroxyindole-3-acetic Acid) at Screen-printed Carbon Electrodes
Popis výsledku v původním jazyce
Three tumor biomarkers (homovanillic acidn(HVA), vanillylmandelic acid (VMA), and 5-hydroxyindole-n3-acetic acid (5-HIAA)) have been determined byndifferential pulse voltammetry (DPV) at screen-printedncarbon electrodes (SPCEs). As an optimum medium fornall three analytes, Britton-Robinson buffer (0.04 mol·L 1,npH 3.0) was used. Dependencies of the peak current onnthe concentration of a biomarker were linear in the concentrationnrange from 0.2 to 100 mmol·L 1 for all thentested compounds, with the limits of quantificationn0.8 mmol·L 1 for homovanillic acid, 0.2 mmol·L 1 for vanillylmandelicnacid, and 0.4 mmol·L 1 for 5-hydroxyindole-n3-acetic acid. Moreover, it was verified that thennewly developed methods can be used for simultaneousndetermination of HVA and VMA in mixture.
Název v anglickém jazyce
Voltammetric Determination of Tumor Biomarkers for Neuroblastoma (Homovanillic Acid, Vanillylmandelic Acid, and 5-Hydroxyindole-3-acetic Acid) at Screen-printed Carbon Electrodes
Popis výsledku anglicky
Three tumor biomarkers (homovanillic acidn(HVA), vanillylmandelic acid (VMA), and 5-hydroxyindole-n3-acetic acid (5-HIAA)) have been determined byndifferential pulse voltammetry (DPV) at screen-printedncarbon electrodes (SPCEs). As an optimum medium fornall three analytes, Britton-Robinson buffer (0.04 mol·L 1,npH 3.0) was used. Dependencies of the peak current onnthe concentration of a biomarker were linear in the concentrationnrange from 0.2 to 100 mmol·L 1 for all thentested compounds, with the limits of quantificationn0.8 mmol·L 1 for homovanillic acid, 0.2 mmol·L 1 for vanillylmandelicnacid, and 0.4 mmol·L 1 for 5-hydroxyindole-n3-acetic acid. Moreover, it was verified that thennewly developed methods can be used for simultaneousndetermination of HVA and VMA in mixture.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-02815S" target="_blank" >GA15-02815S: Nové rozpoznávací principy a přístupy k elektrochemické detekci nádorových markerů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
146-153
Kód UT WoS článku
000394995900020
EID výsledku v databázi Scopus
2-s2.0-85009289946