Determination of Three Tumor Biomarkers (Homovanillic Acid, Vanillylmandelic Acid, and 5‐Hydroxyindole‐3‐Acetic Acid) Using Flow Injection Analysis with Amperometric Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F19%3A00498457" target="_blank" >RIV/61388955:_____/19:00498457 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/19:10393969
Výsledek na webu
<a href="http://hdl.handle.net/11104/0290822" target="_blank" >http://hdl.handle.net/11104/0290822</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201800540" target="_blank" >10.1002/elan.201800540</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Three Tumor Biomarkers (Homovanillic Acid, Vanillylmandelic Acid, and 5‐Hydroxyindole‐3‐Acetic Acid) Using Flow Injection Analysis with Amperometric Detection
Popis výsledku v původním jazyce
Flow injection analysis with amperometric detection (FIA‐AD) at screen‐printed carbon electrodes (SPCEs) in optimum medium of Britton‐Robinson buffer (0.04 mol ⋅ L−1, pH 2.0) was used for the determination of three tumor biomarkers (homovanillic acid (HVA), vanillylmandelic acid (VMA), and 5‐hydroxyindole‐3‐acetic acid (5‐HIAA)). Dependences of the peak current on the concentration of biomarkers were linear in the whole tested concentration range from 0.05 to 100 μmol ⋅ L−1, with limits of detection (LODs) of 0.065 μmol ⋅ L−1 for HVA, 0.053 μmol ⋅ L−1 for VMA, and 0.033 μmol ⋅ L−1 for 5‐HIAA (calculated from peak heights), and 0.024 μmol ⋅ L−1 for HVA, 0.020 μmol ⋅ L−1 for VMA, and 0.012 μmol ⋅ L−1 for 5‐HIAA (calculated from peak areas), respectively.n
Název v anglickém jazyce
Determination of Three Tumor Biomarkers (Homovanillic Acid, Vanillylmandelic Acid, and 5‐Hydroxyindole‐3‐Acetic Acid) Using Flow Injection Analysis with Amperometric Detection
Popis výsledku anglicky
Flow injection analysis with amperometric detection (FIA‐AD) at screen‐printed carbon electrodes (SPCEs) in optimum medium of Britton‐Robinson buffer (0.04 mol ⋅ L−1, pH 2.0) was used for the determination of three tumor biomarkers (homovanillic acid (HVA), vanillylmandelic acid (VMA), and 5‐hydroxyindole‐3‐acetic acid (5‐HIAA)). Dependences of the peak current on the concentration of biomarkers were linear in the whole tested concentration range from 0.05 to 100 μmol ⋅ L−1, with limits of detection (LODs) of 0.065 μmol ⋅ L−1 for HVA, 0.053 μmol ⋅ L−1 for VMA, and 0.033 μmol ⋅ L−1 for 5‐HIAA (calculated from peak heights), and 0.024 μmol ⋅ L−1 for HVA, 0.020 μmol ⋅ L−1 for VMA, and 0.012 μmol ⋅ L−1 for 5‐HIAA (calculated from peak areas), respectively.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
303-308
Kód UT WoS článku
000459630500018
EID výsledku v databázi Scopus
2-s2.0-85055247557