A new type of tubular detector (TD+AuxE) was proposed, fabricated, tested and comparednwith a typical silver amalgam tubular detector developed earlier. Non-stop-flow differentialnpulse voltammetric anodic stripping method (AS-DPV) and amperometric method in anglucose oxidase biosensor arrangement were tested. Both detectors were applied for AS-DPVnmeasurements in flow systems for the first time. The proposed combination of tubularndetector with auxiliary electrode provides a much greater current response than the classicnarrangement with three individual electrodes. All relevant parameters (potentials ofnaccumulation or detection, flow rate, analyte concentrations, shielding sleeve length, etc.)nwere optimized for the developed TD+AuxE.
Název v anglickém jazyce
Electrochemical Measurements in Flow Systems on Silver Amalgam Tubular Detector Combined with Auxiliary Electrode
Popis výsledku anglicky
A new type of tubular detector (TD+AuxE) was proposed, fabricated, tested and comparednwith a typical silver amalgam tubular detector developed earlier. Non-stop-flow differentialnpulse voltammetric anodic stripping method (AS-DPV) and amperometric method in anglucose oxidase biosensor arrangement were tested. Both detectors were applied for AS-DPVnmeasurements in flow systems for the first time. The proposed combination of tubularndetector with auxiliary electrode provides a much greater current response than the classicnarrangement with three individual electrodes. All relevant parameters (potentials ofnaccumulation or detection, flow rate, analyte concentrations, shielding sleeve length, etc.)nwere optimized for the developed TD+AuxE.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVIII. Moderní elektrochemické metody. Sborník přednášek
ISBN
978-80-905221-6-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
114-118
Název nakladatele
Best Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
21. 5. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000464596500026