Optical Near-Field Electron Microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F21%3A00544249" target="_blank" >RIV/61388955:_____/21:00544249 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0321279" target="_blank" >http://hdl.handle.net/11104/0321279</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1103/PhysRevApplied.16.014008" target="_blank" >10.1103/PhysRevApplied.16.014008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optical Near-Field Electron Microscopy
Popis výsledku v původním jazyce
The imaging of dynamical processes at interfaces and on the nanoscale is of great importance throughout science and technology. While light-optical imaging techniques often cannot provide the necessary spatial resolution, electron-optical techniques damage the specimen and cause dose-induced artifacts. Here, optical near-field electron microscopy (ONEM) is proposed, an imaging technique that combines noninvasive probing with light, with a high-spatial-resolution readout via electron optics. Close to the specimen, the optical near fields are converted into a spatially varying electron flux using a planar photocathode. The electron flux is imaged using low-energy electron microscopy, enabling label-free nanometric resolution without the need to scan a probe across the sample. The specimen is never exposed to damaging electrons.
Název v anglickém jazyce
Optical Near-Field Electron Microscopy
Popis výsledku anglicky
The imaging of dynamical processes at interfaces and on the nanoscale is of great importance throughout science and technology. While light-optical imaging techniques often cannot provide the necessary spatial resolution, electron-optical techniques damage the specimen and cause dose-induced artifacts. Here, optical near-field electron microscopy (ONEM) is proposed, an imaging technique that combines noninvasive probing with light, with a high-spatial-resolution readout via electron optics. Close to the specimen, the optical near fields are converted into a spatially varying electron flux using a planar photocathode. The electron flux is imaged using low-energy electron microscopy, enabling label-free nanometric resolution without the need to scan a probe across the sample. The specimen is never exposed to damaging electrons.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GX19-26854X" target="_blank" >GX19-26854X: Souhra lipidů, iontů a bílkovin a její role v dynamice a funkci buněčných membrán</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physical Review Applied
ISSN
2331-7019
e-ISSN
2331-7019
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
014008
Kód UT WoS článku
000677430000002
EID výsledku v databázi Scopus
2-s2.0-85109284871