An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F23%3A00572488" target="_blank" >RIV/61388955:_____/23:00572488 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/23:10478221
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Popis výsledku v původním jazyce
An amperometric biosensor consisting of an enzymatic mini-reactor (lactate oxidase covalentlynattached to −NH2 functionalized mesoporous silica powder SBA−15 using glutaraldehyde) andna silver amalgam-based screen-printed electrode acting as a transducer was developed for thendetermination of L-lactic acid (LA) in FIA. The detection potential of −0.9 V vs. Ag pseudoreferencenelectrode was applied for cathodic detection of enzymatically consumed oxygen.nUnder the optimized conditions, the constructed biosensor enabled selective determination ofnLA with a micromolar limit of detection. Importantly, the proposed biosensor representednexcellent operational stability after ≥350 measurements. Finally, it was successfully applied tonreal sample analysis.
Název v anglickém jazyce
An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Popis výsledku anglicky
An amperometric biosensor consisting of an enzymatic mini-reactor (lactate oxidase covalentlynattached to −NH2 functionalized mesoporous silica powder SBA−15 using glutaraldehyde) andna silver amalgam-based screen-printed electrode acting as a transducer was developed for thendetermination of L-lactic acid (LA) in FIA. The detection potential of −0.9 V vs. Ag pseudoreferencenelectrode was applied for cathodic detection of enzymatically consumed oxygen.nUnder the optimized conditions, the constructed biosensor enabled selective determination ofnLA with a micromolar limit of detection. Importantly, the proposed biosensor representednexcellent operational stability after ≥350 measurements. Finally, it was successfully applied tonreal sample analysis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Moderní elektrochemické metody /42./. Sborník přednášek
ISBN
978-80-908947-0-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
213-217
Název nakladatele
Best servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
22. 5. 2023
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—