An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F23%3A10478221" target="_blank" >RIV/00216208:11310/23:10478221 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.bestservis.eu/realizovane-akce/42-mem/43/" target="_blank" >https://www.bestservis.eu/realizovane-akce/42-mem/43/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Popis výsledku v původním jazyce
An amperometric biosensor consisting of an enzymatic mini-reactor (lactate oxidase covalently attached to −NH2 functionalized mesoporous silica powder SBA−15 using glutaraldehyde) and a silver amalgam-based screen-printed electrode acting as a transducer was developed for the determination of L-lactic acid (LA) in FIA. The detection potential of −0.9 V vs. Ag pseudoreference electrode was applied for cathodic detection of enzymatically consumed oxygen. Under the optimized conditions, the constructed biosensor enabled selective determination of LA with a micromolar limit of detection. Importantly, the proposed biosensor represented excellent operational stability after ≥350 measurements. Finally, it was successfully applied to real sample analysis.
Název v anglickém jazyce
An Enzymatic Biosensor with Amperometric Detection in a Flow Injection Analysis for the Determination of L-lactic Acid: Development and Application
Popis výsledku anglicky
An amperometric biosensor consisting of an enzymatic mini-reactor (lactate oxidase covalently attached to −NH2 functionalized mesoporous silica powder SBA−15 using glutaraldehyde) and a silver amalgam-based screen-printed electrode acting as a transducer was developed for the determination of L-lactic acid (LA) in FIA. The detection potential of −0.9 V vs. Ag pseudoreference electrode was applied for cathodic detection of enzymatically consumed oxygen. Under the optimized conditions, the constructed biosensor enabled selective determination of LA with a micromolar limit of detection. Importantly, the proposed biosensor represented excellent operational stability after ≥350 measurements. Finally, it was successfully applied to real sample analysis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference 42. Moderní Elektrochemické Metody
ISBN
978-80-908947-0-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
213-217
Název nakladatele
Lenka Srsenová - BEST Servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetrichovice, Česká republika
Datum konání akce
22. 5. 2023
Typ akce podle státní příslušnosti
EUR - Evropská akce