Detection of hydrogen peroxide in Photosystem II (PSII) using catalytic amperometric biosensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F15%3A33155875" target="_blank" >RIV/61989592:15310/15:33155875 - isvavai.cz</a>
Výsledek na webu
<a href="http://journal.frontiersin.org/article/10.3389/fpls.2015.00862/full" target="_blank" >http://journal.frontiersin.org/article/10.3389/fpls.2015.00862/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fpls.2015.00862" target="_blank" >10.3389/fpls.2015.00862</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of hydrogen peroxide in Photosystem II (PSII) using catalytic amperometric biosensor
Popis výsledku v původním jazyce
Hydrogen peroxide (H2O2) is known to be generated in Photosystem II (PSII) via enzymatic and non-enzymatic pathways. Detection of H2O2 by different spectroscopic techniques has been explored; however, its sensitive detection has always been a challenge in photosynthetic research. During the recent past, fluorescence probes such as Amplex Red has been used but is known to either lack specificity or limitation with respect to the minimum detection limit of H2O2. We have employed an electrochemical biosensor for real time monitoring of H2O2 generation at the level of sub-cellular organelles. The electrochemical biosensor comprises of counter electrode and working electrodes. The counter electrode is a platinum plate while the working electrode is a mediator based catalytic amperometric biosensor device developed by the coating of a carbon electrode with osmium-horseradish peroxidase which acts as H2O2 detection sensor. In the current study, generation and kinetic behavior of H2O2 in PSII
Název v anglickém jazyce
Detection of hydrogen peroxide in Photosystem II (PSII) using catalytic amperometric biosensor
Popis výsledku anglicky
Hydrogen peroxide (H2O2) is known to be generated in Photosystem II (PSII) via enzymatic and non-enzymatic pathways. Detection of H2O2 by different spectroscopic techniques has been explored; however, its sensitive detection has always been a challenge in photosynthetic research. During the recent past, fluorescence probes such as Amplex Red has been used but is known to either lack specificity or limitation with respect to the minimum detection limit of H2O2. We have employed an electrochemical biosensor for real time monitoring of H2O2 generation at the level of sub-cellular organelles. The electrochemical biosensor comprises of counter electrode and working electrodes. The counter electrode is a platinum plate while the working electrode is a mediator based catalytic amperometric biosensor device developed by the coating of a carbon electrode with osmium-horseradish peroxidase which acts as H2O2 detection sensor. In the current study, generation and kinetic behavior of H2O2 in PSII
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Plant Science
ISSN
1664-462X
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
862
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000364241800001