A SIFT Study of Reactions of Positive and Negative Ions With Polyfluoroalkyl (PFAS) Molecules in Dry and Humid Nitrogen at 393 K
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F25%3A00618617" target="_blank" >RIV/61388955:_____/25:00618617 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0369004" target="_blank" >https://hdl.handle.net/11104/0369004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/rcm.9975" target="_blank" >10.1002/rcm.9975</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A SIFT Study of Reactions of Positive and Negative Ions With Polyfluoroalkyl (PFAS) Molecules in Dry and Humid Nitrogen at 393 K
Popis výsledku v původním jazyce
RationaleData are required for SIFT-MS analysis of perfluoroalkyl and polyfluoroalkyl substances (PFAS), which are persistent in the environment and cause adverse health effects. Specifically, the rate coefficients and product ion branching ratios of the reactions of H3O+, NO+, O2+center dot, O-center dot, OH-, O2-center dot, NO2- and NO3- with PFAS vapours are needed.MethodsThe dual polarity SIFT-MS instrument (Voice200) was used to generate these eight reagent ions and inject them into the flow tube with N2 carrier gas at a temperature of 393 K. Vapours of pentafluoropropionic acid, heptafluorobutyric acid, nonafluoro-1-hexanol, perfluoro-2-methyl-2-pentene, perfluorohexanoic acid, perfluoro(2-methyl-3-oxahexanoic) acid, tridecafluoro-1-octanol and nonafluorobutane-1-sulfonic acid were introduced in dry and humid air. Full-scan mass spectra were collected for all reagents at variable PFAS concentrations and analysed numerically.ResultsRate coefficients were determined for 64 reactions, for which 55 positive and 71 negative product ions were identified. The branching ratios for the primary reaction channels were extracted from the data, and the secondary chemistry with H2O molecules was qualitatively assessed. The thermochemical data were calculated for the H3O+ reactions using density functional theory (DFT).ConclusionsAn important observation is that secondary reactions with water molecules remove the positive product ions, making them unsuitable for practical SIFT-MS analysis of PFAS vapours. In contrast, most negative reaction product ions are not significantly affected by humidity and are thus preferred for the SIFT-MS analyses of PFAS substances in various gaseous matrices.
Název v anglickém jazyce
A SIFT Study of Reactions of Positive and Negative Ions With Polyfluoroalkyl (PFAS) Molecules in Dry and Humid Nitrogen at 393 K
Popis výsledku anglicky
RationaleData are required for SIFT-MS analysis of perfluoroalkyl and polyfluoroalkyl substances (PFAS), which are persistent in the environment and cause adverse health effects. Specifically, the rate coefficients and product ion branching ratios of the reactions of H3O+, NO+, O2+center dot, O-center dot, OH-, O2-center dot, NO2- and NO3- with PFAS vapours are needed.MethodsThe dual polarity SIFT-MS instrument (Voice200) was used to generate these eight reagent ions and inject them into the flow tube with N2 carrier gas at a temperature of 393 K. Vapours of pentafluoropropionic acid, heptafluorobutyric acid, nonafluoro-1-hexanol, perfluoro-2-methyl-2-pentene, perfluorohexanoic acid, perfluoro(2-methyl-3-oxahexanoic) acid, tridecafluoro-1-octanol and nonafluorobutane-1-sulfonic acid were introduced in dry and humid air. Full-scan mass spectra were collected for all reagents at variable PFAS concentrations and analysed numerically.ResultsRate coefficients were determined for 64 reactions, for which 55 positive and 71 negative product ions were identified. The branching ratios for the primary reaction channels were extracted from the data, and the secondary chemistry with H2O molecules was qualitatively assessed. The thermochemical data were calculated for the H3O+ reactions using density functional theory (DFT).ConclusionsAn important observation is that secondary reactions with water molecules remove the positive product ions, making them unsuitable for practical SIFT-MS analysis of PFAS vapours. In contrast, most negative reaction product ions are not significantly affected by humidity and are thus preferred for the SIFT-MS analyses of PFAS substances in various gaseous matrices.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-25486S" target="_blank" >GA21-25486S: Hmotnostní spektrometrie v proudové a driftové trubici s vybranými ionty s negativními ionty a dusíkem jako nosným plynem</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Rapid Communications in Mass Spectrometry
ISSN
0951-4198
e-ISSN
1097-0231
Svazek periodika
39
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
e9975
Kód UT WoS článku
001383360600001
EID výsledku v databázi Scopus
2-s2.0-85213079219