Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F17%3A00482600" target="_blank" >RIV/61388963:_____/17:00482600 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/17:10365545
Výsledek na webu
<a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >http://dx.doi.org/10.1021/acs.analchem.7b02568</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >10.1021/acs.analchem.7b02568</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
Popis výsledku v původním jazyce
The analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.
Název v anglickém jazyce
Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
Popis výsledku anglicky
The analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Chemistry
ISSN
0003-2700
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
21
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
11452-11459
Kód UT WoS článku
000414887000043
EID výsledku v databázi Scopus
—