Toward Accurate Conformational Energies of Smaller Peptides and Medium-Sized Macrocycles: MPCONF196 Benchmark Energy Data Set
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F18%3A00489837" target="_blank" >RIV/61388963:_____/18:00489837 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1021/acs.jctc.7b01074" target="_blank" >http://dx.doi.org/10.1021/acs.jctc.7b01074</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.jctc.7b01074" target="_blank" >10.1021/acs.jctc.7b01074</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Toward Accurate Conformational Energies of Smaller Peptides and Medium-Sized Macrocycles: MPCONF196 Benchmark Energy Data Set
Popis výsledku v původním jazyce
A carefully selected set of acyclic and cyclic model peptides and several other macrocycles, comprising 13 compounds in total, has been used to calibrate the accuracy of the DFT(-D3) method for conformational energies, employing BP86, PBEO, PBE, B3LYP, BLYP, TPSS, TPSSh, M06-2X, B97-D, OLYP, revPBE, M06-L, SCAN, revTPSS, BH-LYP, and omega B97X-D3 functionals. Both high-and low-energy conformers, 15 or 16 for each compound adding to 196 in total, denoted as the MPCONF196 data set, were included, and the reference values were obtained by the composite protocol, yielding the CCSD(T)/CBS extrapolated energies or their DLPNO-CCSD(T)/CBS equivalents in the case of larger systems. The latter was shown to be in near-quantitative (similar to 0.10-0.15 kcal.mol(-1)) agreement with the canonical CCSD(T), provided the TightPNO setting is used, and, therefore, can be used as the reference for larger systems (likely up to 150-200 atoms) for the problem studied here. At the same time, it was found that many D3-corrected DFT functionals provide results of similar to 1 kcal.mol(-1) accuracy, which we consider as quite encouraging. This result implies that DFT-D3 methods can be, for example, safely used in efficient conformational sampling algorithms. Specifically, the DFT-D3/DZVP-DFT level of calculation seems to be the best trade-off between computational cost and accuracy. Based on the calculated data, we have not found any cheaper variant for the treatment of conformational energies, since the semiempirical methods (including DFTB) provide results of inferior accuracy (errors of 3-5 kcal.mol(-1)).
Název v anglickém jazyce
Toward Accurate Conformational Energies of Smaller Peptides and Medium-Sized Macrocycles: MPCONF196 Benchmark Energy Data Set
Popis výsledku anglicky
A carefully selected set of acyclic and cyclic model peptides and several other macrocycles, comprising 13 compounds in total, has been used to calibrate the accuracy of the DFT(-D3) method for conformational energies, employing BP86, PBEO, PBE, B3LYP, BLYP, TPSS, TPSSh, M06-2X, B97-D, OLYP, revPBE, M06-L, SCAN, revTPSS, BH-LYP, and omega B97X-D3 functionals. Both high-and low-energy conformers, 15 or 16 for each compound adding to 196 in total, denoted as the MPCONF196 data set, were included, and the reference values were obtained by the composite protocol, yielding the CCSD(T)/CBS extrapolated energies or their DLPNO-CCSD(T)/CBS equivalents in the case of larger systems. The latter was shown to be in near-quantitative (similar to 0.10-0.15 kcal.mol(-1)) agreement with the canonical CCSD(T), provided the TightPNO setting is used, and, therefore, can be used as the reference for larger systems (likely up to 150-200 atoms) for the problem studied here. At the same time, it was found that many D3-corrected DFT functionals provide results of similar to 1 kcal.mol(-1) accuracy, which we consider as quite encouraging. This result implies that DFT-D3 methods can be, for example, safely used in efficient conformational sampling algorithms. Specifically, the DFT-D3/DZVP-DFT level of calculation seems to be the best trade-off between computational cost and accuracy. Based on the calculated data, we have not found any cheaper variant for the treatment of conformational energies, since the semiempirical methods (including DFTB) provide results of inferior accuracy (errors of 3-5 kcal.mol(-1)).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chemical Theory and Computation
ISSN
1549-9618
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
1254-1266
Kód UT WoS článku
000427661400010
EID výsledku v databázi Scopus
2-s2.0-85043998487