Popis výsledku v původním jazyce
The throttling process in a small-diameter tube ? capillary tube ? was experimentally investigated in this study. A special testing capillary tube equipped with precise temperature and pressure sensors was used to describe the effect of gas impurities, i.e. non-condensing gases (nitrogen in our case), on the flow of throttled refrigerant R218. Total pressure at the onset of vaporization was increased by partial pressure of contaminating gas. Therefore, the two-phase flow of gas-contaminated refrigerantstarted to be generated notably earlier than in the case of pure refrigerant flow. Mass flow rate of refrigerant delivered through capillary tube decreased even by 20 % in some cases. The experimental data were compared with a numerical simulation of pure refrigerant flow in capillary tube.
Název v anglickém jazyce
Experimental Investigation of Throttling Process Affected by Gas Impurities
Popis výsledku anglicky
The throttling process in a small-diameter tube ? capillary tube ? was experimentally investigated in this study. A special testing capillary tube equipped with precise temperature and pressure sensors was used to describe the effect of gas impurities, i.e. non-condensing gases (nitrogen in our case), on the flow of throttled refrigerant R218. Total pressure at the onset of vaporization was increased by partial pressure of contaminating gas. Therefore, the two-phase flow of gas-contaminated refrigerantstarted to be generated notably earlier than in the case of pure refrigerant flow. Mass flow rate of refrigerant delivered through capillary tube decreased even by 20 % in some cases. The experimental data were compared with a numerical simulation of pure refrigerant flow in capillary tube.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental Fluid Mechanics 2009
ISBN
978-80-7372-538-9
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Technical University of Liberec
Místo vydání
Liberec
Místo konání akce
Liberec
Datum konání akce
25. 11. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—