Numerical simulation of gas-contaminated refrigerant two-phase flow through
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F10%3A00346592" target="_blank" >RIV/61388998:_____/10:00346592 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical simulation of gas-contaminated refrigerant two-phase flow through
Popis výsledku v původním jazyce
An unfavorable effect of gas impurities on the throttling process inside a capillary tube has been studied. A special testing capillary tube has been used for an experimental investigation of the capillary flow of a fluorocarbon refrigerant R218 contaminated by nitrogen. The gas impurities significantly affected the throttling process, since the two-phase flow started notably earlier than in the case of pure refrigerant flow. Moreover, the gas contamination resulted in a decreased mass flow rate. A comprehensive numerical model has been developed to simulate the capillary flow of gas-contaminated refrigerant. The model takes into account two coincident thermodynamic events: the throttling process of the refrigerant and the gradual release of the dissolved gas impurities from the refrigerant liquid phase. The model considers adiabatic, thermodynamically equilibrated capillary flow with homogeneous two-phase flow. The numerical simulation is in good agreement with our experimental data.
Název v anglickém jazyce
Numerical simulation of gas-contaminated refrigerant two-phase flow through
Popis výsledku anglicky
An unfavorable effect of gas impurities on the throttling process inside a capillary tube has been studied. A special testing capillary tube has been used for an experimental investigation of the capillary flow of a fluorocarbon refrigerant R218 contaminated by nitrogen. The gas impurities significantly affected the throttling process, since the two-phase flow started notably earlier than in the case of pure refrigerant flow. Moreover, the gas contamination resulted in a decreased mass flow rate. A comprehensive numerical model has been developed to simulate the capillary flow of gas-contaminated refrigerant. The model takes into account two coincident thermodynamic events: the throttling process of the refrigerant and the gradual release of the dissolved gas impurities from the refrigerant liquid phase. The model considers adiabatic, thermodynamically equilibrated capillary flow with homogeneous two-phase flow. The numerical simulation is in good agreement with our experimental data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F09%2F1633" target="_blank" >GA101/09/1633: Vývoj a aplikace nových experimentálních metod pro měření heterogenních částic v přehřáté páře</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Heat and Mass Transfer
ISSN
0017-9310
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
23-24
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000282155900043
EID výsledku v databázi Scopus
—