Infrared Thermography as a Visualization Tool of Flow Control by Vortex Generators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F10%3A00351444" target="_blank" >RIV/61388998:_____/10:00351444 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/10:00181081
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Infrared Thermography as a Visualization Tool of Flow Control by Vortex Generators
Popis výsledku v původním jazyce
This paper focuses on a suppression of the flow separation, which occurs on a deflected flap, by means of vortex generators (VG's). An airfoil NACA 63A421 with a simple flap and vane-type vortex generators were used. The investigation was carried out byusing experimental and numerical methods. The data from the numerical simulation of the flapped airfoil without VG's control were used for the vortex generator design. Two sizes, two different shapes and various spacing of the vortex generators were tested. The flow past the airfoil was visualized through two methods, namely oil and infrared thermography visualization. The lift curves for both cases without and with vortex generators were acquired for a lift coefficient improvement determination. . Theexperiments were performed in closed circuit wind tunnels with open and close test sections. The improvement was achieved for several cases by means all of the applied methods.
Název v anglickém jazyce
Infrared Thermography as a Visualization Tool of Flow Control by Vortex Generators
Popis výsledku anglicky
This paper focuses on a suppression of the flow separation, which occurs on a deflected flap, by means of vortex generators (VG's). An airfoil NACA 63A421 with a simple flap and vane-type vortex generators were used. The investigation was carried out byusing experimental and numerical methods. The data from the numerical simulation of the flapped airfoil without VG's control were used for the vortex generator design. Two sizes, two different shapes and various spacing of the vortex generators were tested. The flow past the airfoil was visualized through two methods, namely oil and infrared thermography visualization. The lift curves for both cases without and with vortex generators were acquired for a lift coefficient improvement determination. . Theexperiments were performed in closed circuit wind tunnels with open and close test sections. The improvement was achieved for several cases by means all of the applied methods.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JU - Aeronautika, aerodynamika, letadla
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Colloquium Fluid Dynamics 2010: Proceedings
ISBN
978-80-87012-27-7
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
Institute of Thermomechanics AS CR, v. v. i.
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
20. 10. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—