Limitations of PWM Rectifier under Unbalanced Voltage Supply
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F10%3A00352055" target="_blank" >RIV/61388998:_____/10:00352055 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Limitations of PWM Rectifier under Unbalanced Voltage Supply
Popis výsledku v původním jazyce
Voltage-unbalance conditions that can arise in the power network may affect operation of electric drives in a negative way. The cause of the unbalance may be a failure in the network or presence of an unbalanced load in the vicinity of the affected drive. Unsymmetrical system of voltages at the input of a voltage source inverter gives rise to the pulsations in the DC-link voltage when no suitable countermeasures are taken. This may result in significantly reduced power capabilities and, therefore, limited controllability of the drive as well as negative influence on the lifetime of the electric motor in the drive. The paper deals with methods to address this problem and with the constraints caused by the unbalanced voltage supply.
Název v anglickém jazyce
Limitations of PWM Rectifier under Unbalanced Voltage Supply
Popis výsledku anglicky
Voltage-unbalance conditions that can arise in the power network may affect operation of electric drives in a negative way. The cause of the unbalance may be a failure in the network or presence of an unbalanced load in the vicinity of the affected drive. Unsymmetrical system of voltages at the input of a voltage source inverter gives rise to the pulsations in the DC-link voltage when no suitable countermeasures are taken. This may result in significantly reduced power capabilities and, therefore, limited controllability of the drive as well as negative influence on the lifetime of the electric motor in the drive. The paper deals with methods to address this problem and with the constraints caused by the unbalanced voltage supply.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1273" target="_blank" >GA102/09/1273: Vliv změn napětí ve stejnosměrném meziobvodu napěťového měniče na chod elektrického pohonu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IET Conference on Power Electronics, Machines and Drives PEMD 2010
ISBN
978-1-84919-231-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institution of Engineering and Technology /IET/
Místo vydání
Brighton
Místo konání akce
Brighton
Datum konání akce
19. 4. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—