Active control of flying capacitor currents in multilevel voltage-source inverters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F13%3A00438517" target="_blank" >RIV/61388998:_____/13:00438517 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Active control of flying capacitor currents in multilevel voltage-source inverters
Popis výsledku v původním jazyce
Analyzed is an output voltage generation technique in multilevel voltage-source inverters with flying capacitors (FLC VSI) utilizing SVM modulation that enables the limitation of voltage ripple across flying capacitors for small modulation depths. This may reduce the capacitance of flying caps in applications where high current overloads are demanded at low AC output voltages, e.g. at motor start. For small modulation depths, the so called zero-voltage vectors must be used in the SVM. the method is based on varying the time distribution of these vectors. By the change of this time distribution, an active control of the currents flowing through the flying capacitors is possible to some extent. The principle of this adaptation is explained, its proprtiesunder steady and transient states are discussed and practical results with 4-level 4 kVA FLC VSI are presented.
Název v anglickém jazyce
Active control of flying capacitor currents in multilevel voltage-source inverters
Popis výsledku anglicky
Analyzed is an output voltage generation technique in multilevel voltage-source inverters with flying capacitors (FLC VSI) utilizing SVM modulation that enables the limitation of voltage ripple across flying capacitors for small modulation depths. This may reduce the capacitance of flying caps in applications where high current overloads are demanded at low AC output voltages, e.g. at motor start. For small modulation depths, the so called zero-voltage vectors must be used in the SVM. the method is based on varying the time distribution of these vectors. By the change of this time distribution, an active control of the currents flowing through the flying capacitors is possible to some extent. The principle of this adaptation is explained, its proprtiesunder steady and transient states are discussed and practical results with 4-level 4 kVA FLC VSI are presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Technica CSAV
ISSN
0001-7043
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
18
Strana od-do
393-410
Kód UT WoS článku
—