Činnost HPGe detektorů v silných magnetických polích
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F07%3A00307556" target="_blank" >RIV/61389005:_____/07:00307556 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performance of HPGe detectors in high magnetic fields
Popis výsledku v původním jazyce
A new generation of high-resolution hypernuclear gamma-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DA Phi NE, the Frascati phi-factory, and at (P) over bar ANDA, the (p) over barp hadron spectrometer at the future FAIR facility. Both, the FINUDA and (P) over bar ANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near thetarget, and therefore they have to be operated in strong magnetic fields (B approximate to I T). The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EUROBALL Cluster HPGe detectorswere tested in the field provided by the ALADiN magnet at GSI. No significant degradation of the energy resolution was found, and a change in the rise time distribution of the pulses from preamplifiers was observed.
Název v anglickém jazyce
Performance of HPGe detectors in high magnetic fields
Popis výsledku anglicky
A new generation of high-resolution hypernuclear gamma-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DA Phi NE, the Frascati phi-factory, and at (P) over bar ANDA, the (p) over barp hadron spectrometer at the future FAIR facility. Both, the FINUDA and (P) over bar ANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near thetarget, and therefore they have to be operated in strong magnetic fields (B approximate to I T). The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EUROBALL Cluster HPGe detectorswere tested in the field provided by the ALADiN magnet at GSI. No significant degradation of the energy resolution was found, and a change in the rise time distribution of the pulses from preamplifiers was observed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BE - Teoretická fyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F05%2F2142" target="_blank" >GA202/05/2142: Studium hyperjader</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
573
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
410-417