Gamma-ray Spectrometer Assembled from 9×CeBr3-NaI(Tl) Phoswich Detectors
Popis výsledku
Identifikátory výsledku
Kód výsledku v IS VaVaI
Výsledek na webu
DOI - Digital Object Identifier
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Gamma-ray Spectrometer Assembled from 9×CeBr3-NaI(Tl) Phoswich Detectors
Popis výsledku v původním jazyce
The technique of using a cluster of 9×CeBr3-NaI(Tl) phoswich detectors as a Compton suppression spectrometer for detecting low-energy Eγ < 4 MeV γ-radiation is investigated. The characteristics of a phoswich detectors cluster and a High-Purity Germanium detector (HPGe) with a BGO shield are compared. The main characteristics of γ-ray spectrometer: the energy resolutions ∆E, the total registration efficiency εγ and the peak efficiency εPEAK, depending on the energies Eγ of the registered γ-rays and on the distances to the source, are presented. It is shown that the Compton suppression coefficient values of both spectrometers are the same, while the peak efficiency of the phoswich cluster is three times higher than in the HPGe detector. The Compton suppression mode of the phoswich cluster is supposed to be used for studying β-delayed γ-decay processes, particularly direct γ-decay of Pygmy resonances.
Název v anglickém jazyce
Gamma-ray Spectrometer Assembled from 9×CeBr3-NaI(Tl) Phoswich Detectors
Popis výsledku anglicky
The technique of using a cluster of 9×CeBr3-NaI(Tl) phoswich detectors as a Compton suppression spectrometer for detecting low-energy Eγ < 4 MeV γ-radiation is investigated. The characteristics of a phoswich detectors cluster and a High-Purity Germanium detector (HPGe) with a BGO shield are compared. The main characteristics of γ-ray spectrometer: the energy resolutions ∆E, the total registration efficiency εγ and the peak efficiency εPEAK, depending on the energies Eγ of the registered γ-rays and on the distances to the source, are presented. It is shown that the Compton suppression coefficient values of both spectrometers are the same, while the peak efficiency of the phoswich cluster is three times higher than in the HPGe detector. The Compton suppression mode of the phoswich cluster is supposed to be used for studying β-delayed γ-decay processes, particularly direct γ-decay of Pygmy resonances.
Klasifikace
Druh
Jimp - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta physica Polonica. B
ISSN
0587-4254
e-ISSN
1509-5770
Svazek periodika
14
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
755-760
Kód UT WoS článku
000742778200014
EID výsledku v databázi Scopus
2-s2.0-85123788792
Druh výsledku
Jimp - Článek v periodiku v databázi Web of Science
OECD FORD
Particles and field physics
Rok uplatnění
2021