Charakterizace polymerů PEEK, PET a PI implantovaných Ni+ ionty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F09%3A00324684" target="_blank" >RIV/61389005:_____/09:00324684 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22310/09:00021552 RIV/44555601:13440/09:00004840
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterisation of Ni+ implanted PEEK, PET and PI
Popis výsledku v původním jazyce
Polyimide (PI), polyetheretherketone (PEEK) and polyethyleneterephthalate (PET) were implanted with 40 keV Ni+ ions at room temperature at fluences ranging from 10^16 to 1.5x10^17 ions cm-2. The depth profiles of the implanted Ni atoms were determined bythe RBS technique and compared with those predicted by the SRIM and TRIDYN codes. Hydrogen depletion as a function of the ion fluence was determined by the ERDA technique, and the compositional and structural changes of the polymers were characterised by the UV?vis and XPS methods. The implanted profiles differed significantly from those predicted by the SRIM code while the lower fluences were satisfactorily described by the TRIDYN simulation. A significant hydrogen release from the polymer surface layer was observed along with significant changes in the surface layer composition. The UV?vis results indicated an increase of the concentration of double bonds, XPS showed increasing concentration Ni0+ with the increasing ion fluence.
Název v anglickém jazyce
Characterisation of Ni+ implanted PEEK, PET and PI
Popis výsledku anglicky
Polyimide (PI), polyetheretherketone (PEEK) and polyethyleneterephthalate (PET) were implanted with 40 keV Ni+ ions at room temperature at fluences ranging from 10^16 to 1.5x10^17 ions cm-2. The depth profiles of the implanted Ni atoms were determined bythe RBS technique and compared with those predicted by the SRIM and TRIDYN codes. Hydrogen depletion as a function of the ion fluence was determined by the ERDA technique, and the compositional and structural changes of the polymers were characterised by the UV?vis and XPS methods. The implanted profiles differed significantly from those predicted by the SRIM code while the lower fluences were satisfactorily described by the TRIDYN simulation. A significant hydrogen release from the polymer surface layer was observed along with significant changes in the surface layer composition. The UV?vis results indicated an increase of the concentration of double bonds, XPS showed increasing concentration Ni0+ with the increasing ion fluence.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
267
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—