Characterization of PEEK, PET and PI implanted with Mn ions and sub-sequently annealed
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F14%3A10285498" target="_blank" >RIV/00216208:11320/14:10285498 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389005:_____/14:00428395 RIV/00216208:11110/14:10285498 RIV/60461373:22310/14:43898179 RIV/44555601:13440/14:43885816
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nimb.2014.01.012" target="_blank" >http://dx.doi.org/10.1016/j.nimb.2014.01.012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nimb.2014.01.012" target="_blank" >10.1016/j.nimb.2014.01.012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of PEEK, PET and PI implanted with Mn ions and sub-sequently annealed
Popis výsledku v původním jazyce
Polyimide (PI), polyetheretherketone (PEEK) and polyethylene terephthalate (PET) foils were implanted with 80 keV Mn+ ions at room temperature at fluencies of 1.0 x 1015-1.0 x 1016 cmMINUS SIGN 2. Mn depth profiles determined by RBS were compared to SRIM2012 and TRIDYN simulations. The processes taking place in implanted polymers under the annealing procedure were followed. The measured projected ranges RP differ slightly from the SRIM and TRIDYN simulation and the depth profiles are significantly broader (up to 2.4 times) than those simulated by SRIM, while TRIDYN simulations were in a reasonable agreement up to the fluence 0.5 x 1016 in PEEK. Oxygen and hydrogen escape from the implanted layer was examined using RBS and ERDA techniques. PET, PEEK and PI polymers exhibit oxygen depletion up to about 40% of its content in virgin polymers. The compositional changes induced by implantation to particular ion fluence are similar for all polymers examined. After annealing no significant ch
Název v anglickém jazyce
Characterization of PEEK, PET and PI implanted with Mn ions and sub-sequently annealed
Popis výsledku anglicky
Polyimide (PI), polyetheretherketone (PEEK) and polyethylene terephthalate (PET) foils were implanted with 80 keV Mn+ ions at room temperature at fluencies of 1.0 x 1015-1.0 x 1016 cmMINUS SIGN 2. Mn depth profiles determined by RBS were compared to SRIM2012 and TRIDYN simulations. The processes taking place in implanted polymers under the annealing procedure were followed. The measured projected ranges RP differ slightly from the SRIM and TRIDYN simulation and the depth profiles are significantly broader (up to 2.4 times) than those simulated by SRIM, while TRIDYN simulations were in a reasonable agreement up to the fluence 0.5 x 1016 in PEEK. Oxygen and hydrogen escape from the implanted layer was examined using RBS and ERDA techniques. PET, PEEK and PI polymers exhibit oxygen depletion up to about 40% of its content in virgin polymers. The compositional changes induced by implantation to particular ion fluence are similar for all polymers examined. After annealing no significant ch
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
ISSN
0168-583X
e-ISSN
—
Svazek periodika
325
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
89-96
Kód UT WoS článku
000334086200014
EID výsledku v databázi Scopus
—