Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F12%3A00384333" target="_blank" >RIV/61389005:_____/12:00384333 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/12:00228798
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10967-012-1709-y" target="_blank" >http://dx.doi.org/10.1007/s10967-012-1709-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-012-1709-y" target="_blank" >10.1007/s10967-012-1709-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez
Popis výsledku v původním jazyce
Multipurpose research reactors require monitoring of neutron flux parameters (alpha, f, F (c) or I broken vertical bar (th) ) during every irradiation of samples when k(0) standardization in neutron activation analysis is to be used, because the above parameters may change quite frequently and unpredictably. We tested two monitor sets consisting of Au+Zr and Au+Mo+Cr for determination of the neutron flux parameters in k(0)-NAA at the LVR-15 reactor in A similar to eA3/4. Based on analysis of several reference materials, we found the use of the Au+Zr monitor set superior over the Au+Mo+Cr monitor set in the specific conditions of the LVR-15 reactor.
Název v anglickém jazyce
Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez
Popis výsledku anglicky
Multipurpose research reactors require monitoring of neutron flux parameters (alpha, f, F (c) or I broken vertical bar (th) ) during every irradiation of samples when k(0) standardization in neutron activation analysis is to be used, because the above parameters may change quite frequently and unpredictably. We tested two monitor sets consisting of Au+Zr and Au+Mo+Cr for determination of the neutron flux parameters in k(0)-NAA at the LVR-15 reactor in A similar to eA3/4. Based on analysis of several reference materials, we found the use of the Au+Zr monitor set superior over the Au+Mo+Cr monitor set in the specific conditions of the LVR-15 reactor.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F09%2F0363" target="_blank" >GA202/09/0363: Klasický a holistický způsob ko standardizace v neutronové aktivační analýze</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
—
Svazek periodika
293
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
10
Strana od-do
665-674
Kód UT WoS článku
000306070700027
EID výsledku v databázi Scopus
—