A new monitor set for the determination of neutron flux parameters in short-time k0-NAA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F11%3A00184333" target="_blank" >RIV/68407700:21340/11:00184333 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389005:_____/11:00366303 RIV/26722445:_____/11:#0000686
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2011.07.050" target="_blank" >http://dx.doi.org/10.1016/j.nima.2011.07.050</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2011.07.050" target="_blank" >10.1016/j.nima.2011.07.050</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A new monitor set for the determination of neutron flux parameters in short-time k0-NAA
Popis výsledku v původním jazyce
Multipurpose research reactors such as LVR-15 in Řež require monitoring of the neutron flux parameters (f, ?) in each batch of samples analyzed when k0 standardization in NAA is to be used. The well-known Au-Zr tri-isotopic monitor set that provides a good tool for determining f and ? after long-time irradiation is not optimal in case of short-time irradiation because only a low activity of the 95Zr radionuclide is formed. Therefore, several elements forming radionuclides with suitable half-lives and Q0and Er parameters in a wide range of values were tested. As a result, an optimal mixture was selected consisting of Au, Mn, and Rb to form a well suited monitor set for irradiation at a thermal neutron fluence rate of 3x1017 m-2 s-1.
Název v anglickém jazyce
A new monitor set for the determination of neutron flux parameters in short-time k0-NAA
Popis výsledku anglicky
Multipurpose research reactors such as LVR-15 in Řež require monitoring of the neutron flux parameters (f, ?) in each batch of samples analyzed when k0 standardization in NAA is to be used. The well-known Au-Zr tri-isotopic monitor set that provides a good tool for determining f and ? after long-time irradiation is not optimal in case of short-time irradiation because only a low activity of the 95Zr radionuclide is formed. Therefore, several elements forming radionuclides with suitable half-lives and Q0and Er parameters in a wide range of values were tested. As a result, an optimal mixture was selected consisting of Au, Mn, and Rb to form a well suited monitor set for irradiation at a thermal neutron fluence rate of 3x1017 m-2 s-1.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
656
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
61-64
Kód UT WoS článku
000296129100008
EID výsledku v databázi Scopus
—