Radiation hardness investigation of avalanche photodiodes for the Projectile Spectator Detector readout at the Compressed Baryonic Matter experiment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00444999" target="_blank" >RIV/61389005:_____/15:00444999 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/15:00315305
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2014.11.071" target="_blank" >http://dx.doi.org/10.1016/j.nima.2014.11.071</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2014.11.071" target="_blank" >10.1016/j.nima.2014.11.071</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radiation hardness investigation of avalanche photodiodes for the Projectile Spectator Detector readout at the Compressed Baryonic Matter experiment
Popis výsledku v původním jazyce
In this paper, we discuss results of avalanche photodiodes radiation tests for Projectile Spectator Detector at future Compressed Baryonic Matter experiment. The tests were carried out in Nuclear Physics Institute of ASCR in Rez using the cyclotron facility. Secondary neutron beam was used for irradiation because the main radiation damage in the Projectile Spectator Detector is caused by neutrons. Two types of the avalanche photodiodes from Zecotek and Ketek manufacturers were investigated. Special attention was given to the noise investigation and self-annealing after the irradiation. We have irradiated two Ketek PM3375 diodes with equivalent dose for 1 MeV neutrons equal to 2.5 +/- 02 x 10(12) n/cm(2), and single Zecotek MAPD-3N diode with equivalentdose for 1 MeV neutrons equal to 3.4 +/- 0.2 x 10(12) n/cm(2). All the types of the diodes haw shown an increasing level of the noise after the irradiation. From that we can conclude that those avalanche photodiodes are not able to detec
Název v anglickém jazyce
Radiation hardness investigation of avalanche photodiodes for the Projectile Spectator Detector readout at the Compressed Baryonic Matter experiment
Popis výsledku anglicky
In this paper, we discuss results of avalanche photodiodes radiation tests for Projectile Spectator Detector at future Compressed Baryonic Matter experiment. The tests were carried out in Nuclear Physics Institute of ASCR in Rez using the cyclotron facility. Secondary neutron beam was used for irradiation because the main radiation damage in the Projectile Spectator Detector is caused by neutrons. Two types of the avalanche photodiodes from Zecotek and Ketek manufacturers were investigated. Special attention was given to the noise investigation and self-annealing after the irradiation. We have irradiated two Ketek PM3375 diodes with equivalent dose for 1 MeV neutrons equal to 2.5 +/- 02 x 10(12) n/cm(2), and single Zecotek MAPD-3N diode with equivalentdose for 1 MeV neutrons equal to 3.4 +/- 0.2 x 10(12) n/cm(2). All the types of the diodes haw shown an increasing level of the noise after the irradiation. From that we can conclude that those avalanche photodiodes are not able to detec
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
787
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
117-120
Kód UT WoS článku
000354869900026
EID výsledku v databázi Scopus
2-s2.0-84919608856