Comparison of cosmic rays radiation detectors on-board commercial jet aircraft
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00445292" target="_blank" >RIV/61389005:_____/15:00445292 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1093/rpd/ncv331" target="_blank" >http://dx.doi.org/10.1093/rpd/ncv331</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncv331" target="_blank" >10.1093/rpd/ncv331</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of cosmic rays radiation detectors on-board commercial jet aircraft
Popis výsledku v původním jazyce
Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energydeposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the adv
Název v anglickém jazyce
Comparison of cosmic rays radiation detectors on-board commercial jet aircraft
Popis výsledku anglicky
Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energydeposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the adv
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LG13031" target="_blank" >LG13031: Spolupráce ČR s CERN</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Radiation Protection Dosimetry
ISBN
—
ISSN
1742-3406
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Oxford Journals
Místo vydání
Oxford
Místo konání akce
Prague
Datum konání akce
1. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—