COMPARISON OF COSMIC RAYS RADIATION DETECTORS ON-BOARD COMMERCIAL JETAIRCRAFT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00229764" target="_blank" >RIV/68407700:21230/15:00229764 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389005:_____/15:00445842 RIV/68407700:21340/15:00229764 RIV/68407700:21670/15:00229764
Výsledek na webu
<a href="http://rpd.oxfordjournals.org/content/early/2015/05/14/rpd.ncv331.full.pdf+html" target="_blank" >http://rpd.oxfordjournals.org/content/early/2015/05/14/rpd.ncv331.full.pdf+html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncv331" target="_blank" >10.1093/rpd/ncv331</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
COMPARISON OF COSMIC RAYS RADIATION DETECTORS ON-BOARD COMMERCIAL JETAIRCRAFT
Popis výsledku v původním jazyce
Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energydeposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the adv
Název v anglickém jazyce
COMPARISON OF COSMIC RAYS RADIATION DETECTORS ON-BOARD COMMERCIAL JETAIRCRAFT
Popis výsledku anglicky
Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energydeposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the adv
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LG13031" target="_blank" >LG13031: Spolupráce ČR s CERN</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
164
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
484-488
Kód UT WoS článku
000356726000006
EID výsledku v databázi Scopus
2-s2.0-84942156242