Nanostructured targets for TNSA laser ion acceleration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F16%3A00460805" target="_blank" >RIV/61389005:_____/16:00460805 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1515/nuka-2016-0018" target="_blank" >http://dx.doi.org/10.1515/nuka-2016-0018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/nuka-2016-0018" target="_blank" >10.1515/nuka-2016-0018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanostructured targets for TNSA laser ion acceleration
Popis výsledku v původním jazyce
Nanostructured targets, based on hydrogenated polymers with embedded nanostructures, were prepared as thin micrometric foils for high-intensity laser irradiation in TNSA regime to produce high-ion acceleration. Experiments were performed at the PALS facility, in Prague, by using 1315 nm wavelength, 300 ps pulse duration and an intensity of 1016 W/cm(2) and at the IPPLM, in Warsaw, by using 800 nm wavelength, 40 fs pulse duration, and an intensity of 1019 W/cm(2). Forward plasma diagnostic mainly uses SiC detectors and ion collectors in time of flight (TOF) configuration. At these intensities, ions can be accelerated at energies above 1 MeV per nucleon. In presence of Au nanoparticles, and/or under particular irradiation conditions, effects of resonant absorption can induce ion acceleration enhancement up to values of the order of 4 MeV per nucleon.
Název v anglickém jazyce
Nanostructured targets for TNSA laser ion acceleration
Popis výsledku anglicky
Nanostructured targets, based on hydrogenated polymers with embedded nanostructures, were prepared as thin micrometric foils for high-intensity laser irradiation in TNSA regime to produce high-ion acceleration. Experiments were performed at the PALS facility, in Prague, by using 1315 nm wavelength, 300 ps pulse duration and an intensity of 1016 W/cm(2) and at the IPPLM, in Warsaw, by using 800 nm wavelength, 40 fs pulse duration, and an intensity of 1019 W/cm(2). Forward plasma diagnostic mainly uses SiC detectors and ion collectors in time of flight (TOF) configuration. At these intensities, ions can be accelerated at energies above 1 MeV per nucleon. In presence of Au nanoparticles, and/or under particular irradiation conditions, effects of resonant absorption can induce ion acceleration enhancement up to values of the order of 4 MeV per nucleon.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nukleonika
ISSN
0029-5922
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
103-108
Kód UT WoS článku
000378086400004
EID výsledku v databázi Scopus
2-s2.0-84976347335