Popis výsledku v původním jazyce
Thermoluminescent detectors are often employed in space dosimetry, characteristic with long duration and exposures to mixed radiation fields. Complementing advantages of this dosimeter type are two drawbacks - dependency of response on radiation quality and signal fading in time. This study investigates fading of the thermoluminescent CaSO4:Dy signal after exposure to some charged components of cosmic radiation, 200 MeV protons and 400 MeV/u carbon ions. The results were compared with the fading after exposure to gamma radiation. The loss of the signal was found to be dependent on the radiation quality, with larger long-term fading for the protons and carbon ions comparing to gamma. For carbon ions, the loss of signal after six months was up to 8%, large enough to justify further study of corrections needed for long term measurements of cosmic radiation.
Název v anglickém jazyce
Fading of CaSO4 thermoluminescent detectors after exposure to charged particles
Popis výsledku anglicky
Thermoluminescent detectors are often employed in space dosimetry, characteristic with long duration and exposures to mixed radiation fields. Complementing advantages of this dosimeter type are two drawbacks - dependency of response on radiation quality and signal fading in time. This study investigates fading of the thermoluminescent CaSO4:Dy signal after exposure to some charged components of cosmic radiation, 200 MeV protons and 400 MeV/u carbon ions. The results were compared with the fading after exposure to gamma radiation. The loss of the signal was found to be dependent on the radiation quality, with larger long-term fading for the protons and carbon ions comparing to gamma. For carbon ions, the loss of signal after six months was up to 8%, large enough to justify further study of corrections needed for long term measurements of cosmic radiation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ15-16622Y" target="_blank" >GJ15-16622Y: Účast v mezinárodním projektu DOSIS-3D</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
106
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
569-572
Kód UT WoS článku
000419417500102
EID výsledku v databázi Scopus
2-s2.0-85012869342