High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part I
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00534293" target="_blank" >RIV/61389005:_____/20:00534293 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1134/S1027451020070320" target="_blank" >https://doi.org/10.1134/S1027451020070320</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1134/S1027451020070320" target="_blank" >10.1134/S1027451020070320</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part I
Popis výsledku v původním jazyce
Three-axis setup using a bent perfect crystal monochromator and analyzer was tested in the diffraction study of alpha-Fe(211) polycrystalline pins with diameters of 8 and 2 mm. After the optimal conditions were realized at a neutron wavelength of 0.162 nm, a high angular resolution was achieved up to FWHM (Delta d/d) = 4.7 x 10(-3)and 3.5 x 10(-3)for 8 and 2 mm pins, respectively, within the range of curvatures of the analyzer used. However, open beams were used, i.e., without Soller collimators. Such a diffraction setting can be used in powder diffraction studies, namely, in the analysis of small changes in the lattice parameters or small changes in the diffraction profile due to the application of an external load.
Název v anglickém jazyce
High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part I
Popis výsledku anglicky
Three-axis setup using a bent perfect crystal monochromator and analyzer was tested in the diffraction study of alpha-Fe(211) polycrystalline pins with diameters of 8 and 2 mm. After the optimal conditions were realized at a neutron wavelength of 0.162 nm, a high angular resolution was achieved up to FWHM (Delta d/d) = 4.7 x 10(-3)and 3.5 x 10(-3)for 8 and 2 mm pins, respectively, within the range of curvatures of the analyzer used. However, open beams were used, i.e., without Soller collimators. Such a diffraction setting can be used in powder diffraction studies, namely, in the analysis of small changes in the lattice parameters or small changes in the diffraction profile due to the application of an external load.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Surface Investigation-X-Ray Synchrotron and Neutron Techniques
ISSN
1027-4510
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
SUPPL 1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
146-150
Kód UT WoS článku
000578828100030
EID výsledku v databázi Scopus
2-s2.0-85092422901