High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part II
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00539686" target="_blank" >RIV/61389005:_____/20:00539686 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1134/S1027451020070332" target="_blank" >https://doi.org/10.1134/S1027451020070332</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1134/S1027451020070332" target="_blank" >10.1134/S1027451020070332</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part II
Popis výsledku v původním jazyce
As a continuation of our recent studies of alpha-Fe(211) samples at a scattering angle of 2 theta(S)= 88 degrees (Part I), a three-axis setup using bent perfect crystal monochromator and several analyzers was tested in the diffraction study of polycrystalline alpha-Fe(110) pins with a diameter of 8 and 2 mm at a scattering angle of 2 theta(S)= 47.1 degrees. After realizing the focusing conditions in real and momentum space at a neutron wavelength of 0.162 nm, a high angular resolution was achieved up to FWHM(Delta d/d) = 1.4 x 10(-3)and FWHM(Delta d/d) = 2.5 x 10(-3)for alpha-Fe samples with a diameter of 2 and 8 mm, respectively. This resolution was obtained by using open beams, i.e., without Soller collimators within the used range of the curvatures of the analyzers. Such settings can be used in powder diffraction, namely, in studies of high-resolution residual stresses and/or analysis of diffraction profiles with a small difference in the lattice parameters or a small change due to the application of an external load.
Název v anglickém jazyce
High-Resolution Analysis Using Bent Perfect Crystal in Powder Diffraction: Part II
Popis výsledku anglicky
As a continuation of our recent studies of alpha-Fe(211) samples at a scattering angle of 2 theta(S)= 88 degrees (Part I), a three-axis setup using bent perfect crystal monochromator and several analyzers was tested in the diffraction study of polycrystalline alpha-Fe(110) pins with a diameter of 8 and 2 mm at a scattering angle of 2 theta(S)= 47.1 degrees. After realizing the focusing conditions in real and momentum space at a neutron wavelength of 0.162 nm, a high angular resolution was achieved up to FWHM(Delta d/d) = 1.4 x 10(-3)and FWHM(Delta d/d) = 2.5 x 10(-3)for alpha-Fe samples with a diameter of 2 and 8 mm, respectively. This resolution was obtained by using open beams, i.e., without Soller collimators within the used range of the curvatures of the analyzers. Such settings can be used in powder diffraction, namely, in studies of high-resolution residual stresses and/or analysis of diffraction profiles with a small difference in the lattice parameters or a small change due to the application of an external load.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Surface Investigation-X-Ray Synchrotron and Neutron Techniques
ISSN
1027-4510
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
SUPPL 1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
151-155
Kód UT WoS článku
000578828100031
EID výsledku v databázi Scopus
2-s2.0-85092365508