Vertical Dosimetric Measurement of Electric Discharge Induced at Lightning Impulse Voltage Generator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F22%3A00560644" target="_blank" >RIV/61389005:_____/22:00560644 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/22:PU146190 RIV/68407700:21340/22:00359548 RIV/68407700:21230/22:00359548
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncac107" target="_blank" >https://doi.org/10.1093/rpd/ncac107</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac107" target="_blank" >10.1093/rpd/ncac107</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Vertical Dosimetric Measurement of Electric Discharge Induced at Lightning Impulse Voltage Generator
Popis výsledku v původním jazyce
This paper deals with the measurement of ionising radiation emitted in the vertical field of electric discharge generated between the tip and the grounded plate electrode. The generator set-up was for 400 consecutive negative discharges with voltage amplitude 0.9 MV, waveform shape 1.2/50 mu s, discharge energy 80 kJ and electrodes 1 m apart. Thermoluminescent, passive detectors were used to avoid electromagnetic interference from the discharge. The detectors were placed at the electrodes and three vertical positions 1 m from the discharge axis. This work extends a previous study focused on dosimetry in the plane parallel to the ground. This experiment confirmed the presence of a photon/electron component at the electrode tip and 0.5 m vertical position at a distance of 1 m from the discharge axis. In addition, the presence of neutrons was found for new positions in the vertical axis and the ground electrode.
Název v anglickém jazyce
Vertical Dosimetric Measurement of Electric Discharge Induced at Lightning Impulse Voltage Generator
Popis výsledku anglicky
This paper deals with the measurement of ionising radiation emitted in the vertical field of electric discharge generated between the tip and the grounded plate electrode. The generator set-up was for 400 consecutive negative discharges with voltage amplitude 0.9 MV, waveform shape 1.2/50 mu s, discharge energy 80 kJ and electrodes 1 m apart. Thermoluminescent, passive detectors were used to avoid electromagnetic interference from the discharge. The detectors were placed at the electrodes and three vertical positions 1 m from the discharge axis. This work extends a previous study focused on dosimetry in the plane parallel to the ground. This experiment confirmed the presence of a photon/electron component at the electrode tip and 0.5 m vertical position at a distance of 1 m from the discharge axis. In addition, the presence of neutrons was found for new positions in the vertical axis and the ground electrode.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10509 - Meteorology and atmospheric sciences
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
198
Číslo periodika v rámci svazku
9-11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
617-622
Kód UT WoS článku
000844405700021
EID výsledku v databázi Scopus
2-s2.0-85137124895